REMOTE MONITORING OPTIONS FOR ABB DRIVES, CONVERTERS AND INVERTERS

NETA-21 remote monitoring tool

Installation and start-up guide

Summary of Contents for NETA-21

Page 1: ...REMOTE MONITORING OPTIONS FOR ABB DRIVES CONVERTERS AND INVERTERS NETA 21 remote monitoring tool Installation and start up guide...

Page 2: ......

Page 3: ...e to the equipment Only qualified electricians are allowed to install and maintain the drive converter and or inverter Disconnect the drive converter or inverter to which the option module will be ins...

Page 4: ...nnector providing a 10BASE T 100BASE TX Ethernet connection for a PC in the public network 6b ETH 2 RJ45 type connector providing a 10BASE T 100BASE TX Ethernet connection for a drive converter or inv...

Page 5: ...rt 9 pin D sub male type connector X2 EIA 232 level interface for a modem 3 X3 EIA 485 port 4 pin detachable screw type connector X3 EIA 485 level interface for a Modbus network 4 Termination jumpers...

Page 6: ...st the NETA 21 2 Tighten the grounding screw A Do not use excessive force Mounting instructions 1 Protect the devices from the drilling dust 2 Drill the holes for the fastening screws of the mounting...

Page 7: ...1 supplies also the NEXA 21 For information on the connector type voltage and power specification see Connectors Note In the NEXA 21 there is an alternative power supply input X11 which you can use fo...

Page 8: ...ABB drive converter or inverter NETA 21 PC PC ETH1 ETH2 Link to Ethernet networks PNL1 PNL2 Note The RJ45 connectors of the control panel are located in the ceiling of the control panel housing Beside...

Page 9: ...tings the NETA 21 can normally auto detect drives converters inverters connected to an NDBU branching unit The NETA 21 auto detects connected devices when the fiber is connected for the first time If...

Page 10: ...a fiber optic link is used MSTR CH0 CH1 NDBU x5 ABB drive converter or inverter T T R R Drive converter inverter 1 to CH0 drive converter inverter 9 to CH8 Tx Rx NEXA 21 PC ETH1 ETH2 NETA 21 PC Link t...

Page 11: ...sed in a networked environment where other DHCP servers exists Make sure that DHCP is enabled on PC Ethernet If the PC Ethernet is on static mode NETA 21 cannot provide dynamic IP to the PC 1 Switch o...

Page 12: ...12 NETA 21 remote monitoring tool Logging on to the NETA 21 When you log on to the NETA 21 for the first time use the default user name password admin admin You are forced to change the password...

Page 13: ...details Change password Adding users To add a user go to Settings Users Add user It is possible to create user accounts with different roles Settings Users Add user User properties User role Setting...

Page 14: ...he NETA 21 and only one drive converter inverter online Connect the drive converter inverter to the NETA 21 The NETA 21 initializes the communication to the drive converter inverter automatically Init...

Page 15: ...orted EXT Off No NEXA 21 connected Green NEXA 21 found and initialized Blinking green NEXA 21 support is being initialized when the remote monitoring tool boots up Red NEXA 21 malfunctions Blinking re...

Page 16: ...twork to be monitored PC ETH 1 Off PC not connected If an Ethernet cable is connected to the PC ETH 1 port but no one uses the tool the LED remains blank Green Connection set up and in operation for e...

Page 17: ...tory settings MON Blinking green NETA 21 sends data eg email to an external destination Blinking red NETA 21 fails to send data eg email to an external destination Log on to the web user interface and...

Page 18: ...e a backup The SD card must have a minimum of 200 MB free space to enable the backup restore functions Backup and restore files are stored in the BACKUP folder on the SD card Create backup creates a b...

Page 19: ...tore file function restores a selected file If restoring requires rebooting full system restore you are prompted to reboot the system If you choose to reboot the remote monitoring tool the reboot view...

Page 20: ...T 100Base TX 10 Mbit s or 100 Mbit s Cable type Shielded twisted pair STP both straight through and crossover cables are supported HP Auto MDIX Connector type Shielded 8P8C modular jack RJ45 Terminat...

Page 21: ...USB host port PHY Interface USB2 0 Connector type Shielded USB Type A Fiber optic transmitter receiver DDCS Media Fiber optic cable Protocol Distributed Drives Communication System DDCS Connectors Da...

Page 22: ...22 NETA 21 remote monitoring tool...

Page 23: ...e contacts can be found by navigating to abb com searchchannels Product training For information on ABB product training navigate to new abb com service training Providing feedback on ABB Drives manua...

Page 24: ...abb com drives Copyright 2019 ABB All rights reserved Specifications subject to change without notice 3AUA0000096881 Rev D EN 2019 12 04...