1.3.2 About emergency stop
The emergency stop
The purpose of the emergency stop function is to avert actual or impending
emergency situations arising from the behavior of persons or from an unexpected
hazardous event.
The emergency stop function is to be initiated by a single human action.
The emergency stop function is a complementary protective measure and shall
not be applied as a substitute for safeguarding measures and other functions or
safety functions.
The effect of an activated emergency stop device is sustained until the actuator
of the emergency stop device has been disengaged. This disengagement is only
possible by an intentional human action on the device where the command has
been initiated. The disengagement of the emergency stop device shall not restart
the machinery but only permit restarting.
Note
The emergency stop device on the FlexPendant is operational when the robot
is powered. Indicators to be used to verify that the robot is powered are the main
switch on the cabinet or the LED indicator on the cabinet when robot is in Motors
On Mode.
Recover from emergency stop
1 Inspect the machinery in order to detect the reason for the emergency stop
device actuation.
2 Locate and disengage the emergency stop device or devices that initiated
the emergency stop function.
22
Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
1 Safety
1.3.2 About emergency stop
Summary of Contents for OmniCore E10
Page 1: ...ROBOTICS Product manual OmniCore E10 ...
Page 8: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 228: ......
Page 229: ......