xx2100001309
PWR_DO
2
24V_IO_EXT
1
GND_DO
4
0V_IO_EXT
3
DO4
6
DO8
5
DO3
8
DO7
7
DO2
10
DO6
9
DO1
12
DO5
11
0V_IO_EXT
14
0V_IO_EXT
13
GND_DI
16
GND_DI
15
DI1
18
DI16
17
DI2
20
DI15
19
DI3
22
DI14
21
DI4
24
DI13
23
DI5
26
DI12
25
DI6
28
DI11
27
DI7
30
DI10
29
DI8
32
DI9
31
The connectors contain 16 digital input signals, 8 digital output signals, 24 V and
0 V for the outputs, and 0 V for the inputs.
CAUTION
The process power supply(PWR_DO, GND_DO) should be supplied separately.
The 24V_IO_EXT rails must handle maximum output current of 4 A in total.
For connection details, see
Circuit diagram - OmniCore E10
,
3HAC076810-008
.
Customer safety interface - X9
Note
The FlexPendant connector can only be used to connect a FlexPendant and
CANNOT be used to connect any other devices.
All external safety devices must be connected from the customer safety interface.
Continues on next page
86
Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
Summary of Contents for OmniCore E10
Page 1: ...ROBOTICS Product manual OmniCore E10 ...
Page 8: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 228: ......
Page 229: ......