Note
Action
Use the correct press plate:
3HAC079878-009
Fit the press plate to the arm house cover, togeth-
er with the M12 screw.
4
xx2300001365
xx2100001270
Press the cover and cassette sealing into place
by rotating the M12 screw.
If used, remove the temporary support screws
before pressing the cover completely into place.
Check that the guide pins are inserted in the arm
house.
5
Torx pan head screw: M6x16
Stainless steel A2-70
Secure the cover with the attachment screws.
Use locking liquid.
6
Locking liquid: - (Loctite 2400 (or
equivalent Loctite 243))
Ensure gap closure between cover and arm
house.
Tightening torque: 10 Nm
xx2100001255
xx2300001367
Remove the tool.
7
See
.
Perform a leak-down test.
8
Continues on next page