Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safe-
guarded space.
5
Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover.
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx2300001366
If DressPack MH3 is installed:
Remove the wrist bracket with the complete
ball joint housing still fitted, if the bracket
is installed over the two wrist screws.
Note
No need to remove the bracket if the two
wrist screws are accessible.
2
xx2100002709
If DressPack is installed:
Open the ball joint housing on the arm tube
and remove the DressPack cable package.
3
Continues on next page
Product manual - IRB 6720
269
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair