Note
Action
xx2200001398
Hold the mechanical stop pin in a firm grip,
and remove it by unscrewing the set screw.
3
See
Floor-mounted robot: Draining the
Begin draining the axis-1 gearbox.
Note
There will be some oil left in the gear after
draining.
4
Disconnecting the axis-1 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Remove the motor cover by removing the
screws.
2
Continues on next page
440
Product manual - IRB 6720
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gearbox
Continued