Note
Action
Hex socket head cap screw: M10x25 8.8-
A3F.
Apply flange sealant and refit the cover
plate on the back of the balancing device.
1
Tightening torque: 50 Nm.
Flange sealant for conical fittings: Loctite
5400 (or equivalent Loctite 577).
xx2200001330
Concluding procedure
Note
Action
If the robot is equipped with DressPack, refit the
brackets of the ball joint housings on the wrist.
1
Remove the lifting accessory from the balancing
device.
2
See
Filling oil into the axis-2 gear-
.
Refill oil to the axis-2 gearbox.
3
See
Calibrate the robot.
4
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page 100
5
518
Product manual - IRB 6720
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.8.2 Replacing the axis-2 gearbox
Continued