Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover.
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx2300001366
If DressPack MH3 is installed:
Remove the wrist bracket with the complete
ball joint housing still fitted, if the bracket
is installed over the two wrist screws.
Note
No need to remove the bracket if the two
wrist screws are accessible.
2
xx2100002709
If DressPack is installed:
Open the ball joint housing on the arm tube
and remove the DressPack cable package.
3
xx2000000373
Remove the wrist cover.
4
Continues on next page
524
Product manual - IRB 6720
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.8.3 Replacing the axis-3 gearbox
Continued
Summary of Contents for OmniCore IRB 6720
Page 1: ...ROBOTICS Product manual IRB 6720...
Page 8: ...This page is intentionally left blank...
Page 14: ...This page is intentionally left blank...
Page 54: ...This page is intentionally left blank...
Page 184: ...This page is intentionally left blank...
Page 584: ...This page is intentionally left blank...
Page 608: ...This page is intentionally left blank...
Page 614: ...This page is intentionally left blank...
Page 639: ......