Note
Action
Torx pan head screw: M5x12 Stainless
steel A2-70
Refit the connector bracket assembly to
the motor.
CAUTION
The cabling is sensitive to mechanical
damage. Handle it with care to avoid dam-
age to the cabling or the connector, avoid
any kind of tilt or skew.
4
xx2200001730
xx2300000920
Verify correct cable layout as shown in the
figure.
CAUTION
Route the signal cabling correctly to avoid
cable damage.
5
Connection box cover MT100X with gasket:
Inspect the gasket.
6
3HAC079381-003 (Graphite White)
Replace if damaged.
3HAC079381-004 (ABB Orange)
xx2200001922
CAUTION
When fitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
7
Continues on next page
Product manual - IRB 6720
561
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.8.3 Replacing the axis-3 gearbox
Continued
Summary of Contents for OmniCore IRB 6720