5.8.2 Replacing the axis-2 gearbox
Space required nearby robot
This section describes how to replace the gearbox without needing to remove the
cable harness and DressPack cable package (if installed) from the robot.
The described procedure requires free space on the floor nearby the robot. There
should be enough space to place foam boards, pallets or similar protective material
nearby the robot.
If needed, run axis-1 into a position that gives the required space. The figure shows
an example.
xx2300000026
Note
Keeping the cable harness and DressPack fitted on the robot during gearbox
replacement is only a recommendation. If it is not possible to put the lower and
upper arm close enough to the robot, the cable harness and DressPack in the
base and in the frame must be removed first.
Continues on next page
476
Product manual - IRB 6720
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.