Removing the internal fan
Preparations
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
.
Open the door.
2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
3
xx2100000318
Removing the internal fan
Note/Illustration
Action
xx2100000342
Remove the screws holding the fan as-
sembly.
1
Remove the fan assembly from the
mounting plate.
2
Disconnect the internal fan:
•
G5.X1-K2.X17
3
Continues on next page
Product manual - OmniCore V250XT
187
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.2.2 Replacing the internal fan
Continued