Note/Illustration
Action
xx2100001283
Remove the internal fan attachment
screws.
4
Refitting the internal fan
Refitting the internal fan
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx2100000318
Continues on next page
188
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.2.2 Replacing the internal fan
Continued