OmniCore V250XT
Reference to circuit diagram
Baseline
X2
Manipulator signal connector
(SMB)
Baseline
X4
FlexPendant connector (HMI)
Baseline
X1
Motor connector
Baseline
A2.K3
Motion Safety
Baseline
i
K7
Connected Services Gateway
(with antenna for 3G and WiFi)
Baseline
G1-G4
Standard fan
Baseline
G5
Internal fan
Baseline
A2
Main computer
Baseline
Q0
Incoming mains switch
Baseline
K2
Robot signal exchange proxy
Baseline
X0
Incoming mains connector
i
Baseline is 3G. Wired or WiFi available as option.
OmniCore V250XT, Options
OmniCore V250XT
Reference to circuit diagram
Option
K5.1
Scalable I/O
Option
K5.2
Additional I/O
K5.3
K5.4
Option
K3.1
Safety digital base I/O
Option
B1
Conveyor tracking module
Option
K4
Ethernet switch
Option
T5, T8
Process power supply
Option
T6, T9
ODVA power supply
Option
Air filter
Option
X0
Incoming mains cable gland
Dimensions
Value
Parameter
650 mm
Width
480 mm
Depth
960 mm
Height
Weight
The table shows the weight of the controller.
Weight
Controller
83 kg
OmniCore V250XT
Continues on next page
Product manual - OmniCore V250XT
37
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
2 Controller description
2.2 Technical data for OmniCore V250XT controller
Continued
Summary of Contents for OmniCore V250XT
Page 1: ...ROBOTICS Product manual OmniCore V250XT ...
Page 34: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 410: ...This page is intentionally left blank ...
Page 418: ...This page is intentionally left blank ...
Page 454: ......
Page 455: ......