Tension Electronics PFEA111/112, User Manual
Chapter 3 Commissioning
3-6
3BSE029380R0101 Rev C
3.8.1 Performing Fast Setup using Hanging Weights
The simplest method to set the wrap gain in this tension system is to use a known weight that
loads the center of the roll with a rope that follows the web path exactly.
Figure 3-1. Setting Wrap Gain with Hanging Weights (example of installation)
Follow the steps below to run a fast setup using hanging weights.
1
Press
for 5 seconds to go to the
FastSetUp
menu.
2
Press
to start the fast setup sequence.
3
The menu SetWebWidth will only be available when the
selected unit is N/m, kN/m, kg/m or pli.
Default Web Width is 2m (78,740 inch).
4
Select
HangingWeights
from the list with
and
.
Confirm with
.
5
Select the number of load cells that support the roll (2 or
Single Side A or Single Side B) from the list with
or
.
Confirm with
.
6
Check the nominal load on the load cell name plate.
Select nominal load from the list with
or
.
Confirm with
.
7
Zero set is used to compensate for load cell zero signal and
tare weight.
Zero set must be done with no tension applied to the roll.
8
1.
Check that no load is applied on the roll.
2.
Press
to zero set. “
ActionDone
” is shown on the
display for one second to confirm the zero setting action.
Load cell
Weight
Rope
supported roll
All rolls must be
free turning idlers.
To keep friction
losses low, only
use the closest
rolls to define web
path.
WebTension
> 5
seconds
FastSetUp
SetWebWidth
[XXXXXX]
SetWrapGain
[HangingWeights]
CellsOnRoll
[2]
NominalLoad
[1 kN 225 lbs]
ZeroSet
[Yes]
WithNoTension
PressOkToZeroSet
Summary of Contents for PFEA 111
Page 30: ...Tension Electronics PFEA111 112 User Manual Chapter 2 Installation 2 14 3BSE029380R0101 Rev C ...