Operation Manual / Power2 845-M / Low-pressure stage
8 Troubleshooting / 8.2 Malfunctions during operation
© Copyright 2022 ABB. All rights reserved.
HZTL4068_EN
Rev.E
March 2022
Increase in high-pressure stage speed
Possible causes
Remedy
High-pressure
stage
Heavy contamination of the nozzle
ring
Contact a Turbo Systems service sta-
tion
Low-pressure stage defective
Contact a Turbo Systems service sta-
tion
Pipes
Leak in exhaust gas pipe before the
low-pressure stage
Repair
Table 32: Malfunctions during operation – Power2 HP speed increases
Exhaust gas temperature too high
Engine performance and engine speed unchanged
Possible causes
Remedy
Engine
Malfunction in the injection system
Repair or contact manufacturer
Low-pressure
or
high-pressure
stage
Insufficient air, for example, because
filter silencer is blocked by contam-
ination
Clean
Compressor/turbine contaminated
Exhaust gas back pressure too high
Clean or repair boiler or exhaust gas si-
lencer
Turbine damaged or eroded
Contact a Turbo Systems service sta-
tion
Charge air
cooler/inter-
cooler
Cooler contaminated
Clean
Cooling water volume too low
Fill
Inlet temperature of cooling water
too high
Check/clean cooling system
Insufficient ventilation
Improve ventilation
Table 33: Malfunctions during operation – Exhaust gas temperature too high
Page
66
/
119