Fieldbus interfaces 103
Data I/O registers 3 ... 53 programmed for the VSN-700 logger:
Holding
register
FbEq (16b/32b),
scaling
Description
Mirrored inverter
parameter
Config
Parameter
Name
3
16b, 10 = 1
DC voltage
101.01
158.104
Data I/O 4
4
16b, 10 = 1
Line current
101.02
158.105
Data I/O 5
5
16b, 100 = 1
Frequency
101.08
158.106
Data I/O 6
6
16b, 10 = 1
Apparent power
101.10
158.107
Data I/O 7
7
16b, 10 = 1
Power
101.10
158.108
Data I/O 8
8
16b, 10 = 1
Reactive power
101.14
158.109
Data I/O 9
9
16b, 100 = 1
CosPhi
101.16
158.110
Data I/O 10
10
16b, 10 = 1
Input current
101.30
158.111
Data I/O 11
11
16b
Tripping fault
104.01
158.112
Data I/O 12
12
16b
Active warning 1
104.06
158.113
Data I/O 13
13
16b
Active warning 2
104.07
158.114
Data I/O 14
14
16b
Active warning 3
104.08
158.115
Data I/O 15
15
16b
Active warning 4
104.09
158.116
Data I/O 16
16
16b
Active warning 5
104.10
158.117
Data I/O 17
17
16b
Latest warning
104.16
158.118
Data I/O 18
18
16b
Main status word
106.11
158.119
Data I/O 19
19
16b
Cpu usage
107.11
158.120
Data I/O 20
20
32b
Connection status
172.01
158.121
Data I/O 21
21
Reserved
Data I/O 22
22
32b
Disconnect diagnostic
172.02
158.123
Data I/O 23
23
Reserved
Data I/O 24
24
32b
Output power diagnostic
172.03
158.125
Data I/O 25
25
Reserved
Data I/O 26
26
32b, 1 = 1
Uptime
173.01
158.127
Data I/O 27
27
Reserved
Data I/O 28
28
16b, 1 = 1
Operation time
173.02
158.129
Data I/O 29
29
16b, 1 = 1
Internal fan speed
173.06
158.130
Data I/O 30
30
16b, 1 = 1
External fan 1 speed
173.07
158.131
Data I/O 31
31
16b, 1 = 1
External fan 2 speed
173.08
158.132
Data I/O 32
32
32b, 1 = 1
Grid connections
173.20
158.133
Data I/O 33
33
Reserved
Data I/O 34
34
16b, 1 = 1
Control board temperature 173.23
158.135
Data I/O 35
35
16b, 1 = 1
Inverter temperature A
173.24
158.136
Data I/O 36
36
16b, 1 = 1
Inverter temperature B
173.25
158.137
Data I/O 37
37
16b, 1 = 1
Inverter temperature C
173.26
158.138
Data I/O 38
38
16b, 100 = 1
Current: [1]
174.50
158.139
Data I/O 39
39
16b, 100 = 1
Current: [2]
174.51
158.140
Data I/O 40
40
16b, 100 = 1
Current: [3]
174.52
158.141
Data I/O 41
41
16b, 100 = 1
Current: [4]
174.53
158.142
Data I/O 42
42
16b, 100 = 1
Current: [5]
174.54
158.143
Data I/O 43
43
16b, 100 = 1
Current: [6]
174.55
158.144
Data I/O 44
44
16b, 100 = 1
Current: [7]
174.56
158.145
Data I/O 45
45
16b, 100 = 1
Current: [8]
174.57
158.146
Data I/O 46
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...