38 Parameters
Reading the parameter listing table
In the parameter listing section, each configuration parameter and its properties are
described. The rows and columns of the parameter listing and how to interpret them are
explained below in
italicized
text.
Example header of the parameter listing table
.
Example parameter indexes: Interpretation of data in the table.
No.
Parameter
group and
index
Name/Value/Range
Parameter name,
value/range and unit
Description
Parameter description
Default
FbEq (16b/32b)
Default value and
Fieldbus equivalent for 16-
bit and 32-bit access.
101 Actual values
Parameter group index and name.
101.01
Parameter
group and
index.
DC voltage
Parameter name
Measured DC link voltage.
Brief description of parameter and
what it does.
-
A dash “-” indicates that
default value is not
applicable.
0 … 2 000 V
Value range and unit.
10 = 1 V /
100 = 1 V
10 = 1 V means 16-bit
access with one decimal.
100 = 1 V means 32-bit
access with two decimals.
- / 1000 = 1 Mohm
A dash “-” means 16-bit
access is not possible.
1000 = 1 Mohm means 32-
bit access only, with three
decimals.
1 = 1 mA
16-bit and 32-bit access
are identical, integers only.
158.04
Baud rate
For parameters with a set
of fixed selection options,
the values are listed in
below rows.
Selects the communication speed of...
For parameters with selection options,
each option is briefly described in
below rows.
19.2 kbps
Default selection
For parameters with fixed
selection options the
fieldbus values are fixed
integers as listed in below
rows.
Autodetect
Automatic baud rate detection.
0
9.6 kbps
Force baud rate to 9 600 bps.
1
19.2 kbps
Force baud rate to 19 200 bps.
2
38.4 kbps
Force baud rate to 38 400 bps.
3
57.6 kbps
Force baud rate to 57 600 bps.
4
76.8 kbps
Force baud rate to 76 800 bps.
5
115.2 kbps
Force baud rate to 115 200 bps.
6
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...