Parameters 89
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
188 Grid monitoring
188.01
Country code
Sets installation country.
Changing this value sets the default and/or
mandatory values for all other country
parameters. This value is initially set by the first
start assistant which is run at first startup of the
inverter.
0
0 … 34
1 = 1
188.02
Nominal LL voltage
Sets nominal line-to-line voltage.
400 V
-
1 = 1 V
188.03
Nominal phase voltage
Sets nominal phase voltage.
230 V
-
1 = 1 V
188.04
Nominal frequency
Sets nominal grid frequency.
50 Hz
-
1 = 1 Hz /
10 = 1 Hz
188.05
Refresh
Refreshes grid monitoring parameter settings.
Done
Done
0
Yes
1
188.06
Voltage source
Selects voltage to be used for checking grid
voltage limits.
Main
Main
0
Phase
1
188.10
Initial connection delay
Sets time delay for initial grid connection.
5 s
-
1 = 1 s
188.11
Reconnection delay
Sets reconnection time delay.
300 s
-
1 = 1 s
188.12
Quick disturbance limit
Sets limit for quick disturbance protection.
0 s
-
1 = 1 s
188.13
Quick reconnection delay
Sets quick reconnection time delay.
5 s
-
1 = 1 s
188.16
External trip
Signals external grid monitoring trip. Inverter is
disconnected from the AC grid.
0
0 … 1
1 = 1
188.19
Zero cross monitor enable Enables zero cross detection in grid monitoring.
1
0 ... 1
1 = 1
188.20
Connect underfrequency
type
Selects connection type for underfrequency
protection.
Disabled
Disabled
Limit is disabled.
0
Disconnected
Limit is enabled when the inverter is disconnected
from the grid.
1
Reconnection
Limit is enabled when inverter trips to
underfrequency.
2
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...