10.3
Fitting the cover plate
u
Remove low-pressure stage (see chapter Removal and installation).
¡
Gas outlet casing removed
u
Fit the turbine casing with the gas outlet casing into the gas pipe again.
u
Attach cover plate.
¡
Gas outlet casing not removed
u
Fit the turbine casing into the gas pipe and on the gas outlet casing again.
u
Attach cover plate.
Fig. 45: Fitting the cover plate
u
Make sure that the oil connections in the bracket are equipped with gaskets.
1. Close the opening in the turbine casing (51000) with the cover plate (01).
2. Thoroughly clean the fastening strips (51002) before assembly.
3. Coat the threads of the studs (51006) with high-temperature grease.
4. Fasten the cover plate on the turbine casing (51000) with fastening strips (51002), Ver-
bus Ripp® washers (51003) and nuts (51007), and screw it onto the bracket.
Part number
Tightening torque [Nm]
51007
M12
75
Table 52: Tightening torques (51007)