9.5
Removing the air inlets
u
Mark the casing position for assembly.
Fig. 23: Removing the air inlets
1. Attach lifting gear to the filter silencer (81000) or air suction branch (82000).
2. Loosen and remove V-clamp (72020).
3. Remove filter silencer (81000) or air suction branch (82000), set it down properly in an
appropriate place and secure it.
4. Remove and dispose of the O-ring (81010 / 82010).