Operation Manual / Power2 340-H / Low-pressure stage
9 Disassembly and assembly / 9.16 Installing the compressor casing
© Copyright 2022 ABB. All rights reserved.
HZTL4053_EN
Rev.F
March 2022
9.16
Installing the compressor casing
Fitting the wall insert and the diffuser
Fig. 38: Fitting the wall insert and the diffuser
Product
Size
Tightening torque [Nm]
Power2 340-H LP
M6
8
Table 46: Tightening torque (79041)
1. Fit new O-ring (77005) (see
).
2. Install the wall insert (77000) into the compressor casing.
3. Secure the diffuser (79000) with fixing discs (79040) and new screws (79041).