Operation Manual / Power2 340-H / Low-pressure stage
9 Disassembly and assembly / 9.7 Removing the compressor casing
© Copyright 2022 ABB. All rights reserved.
HZTL4053_EN
Rev.F
March 2022
Dismantling the wall insert
Fig. 26: Dismantling the wall insert
1. Knock the wall insert (77000) out of the compressor casing (72000) with a plastic tip
hammer.
2. Attach swivel lifting eye (S) to the compressor casing (72000) and the lifting gear.
3. Lift up the compressor casing (72000).
4. Remove and dispose of the O-ring (77005).