The allowed range for the fixing screws’ tightening torque is
0.7...1 Nm.
5.
Install the plug-in unit into the case.
A070579 V4 EN
Figure 15:
Rack mounted IED
4.3.6
Wall mounting the IED
A mounting kit is needed for wall mounting the IED. In addition to the detailed
mounting instructions, the wall mounting kit includes:
•
Wall mounting frame and rail parts
•
Back plate
•
Screws
•
Dimensions for screw holes
1.
Drill screw holes according to the dimensional drawing.
2.
Mount the wall mounting frame and the rails.
3.
Install the back plate.
4.
Loosen the four M5 fixing screws in the case to fit the case into the mounting
frame.
5.
Mount the case between the rails.