background image

The three-phase line side phase voltage inputs to the relay are measured by the three-
phase voltage measurement function VMMXU1 whereas the bus side voltage input to
the relay is measured by the three-phase voltage measurement function VMMXU2.
The three-phase voltage input is connected to the X130 card in the back panel. The
sequence voltage measurement VSMSQI1 measures the sequence voltage and the
residual voltage measurement RESVMMXU1 measures the residual voltage on the
line side.

The measurements can be seen in the LHMI and they are available under the
measurement option in the menu selection. Based on the settings, function blocks can
generate low alarm or warning and high alarm or warning signals for the measured
current values.

The frequency measurement FMMXU1 of the power system and three-phase power
and energy measurement PEMMXU1 are available. Load profile record LDPRLRC1
is included in the measurements sheet. LDPRLRC1 offers the ability to observe the
loading history of the corresponding feeder.

CMMXU1(3I(1))

BLOCK

HIGH_ALARM

HIGH_WARN

LOW_WARN

LOW_ALARM

GUID-96C8ED35-DFCE-46BC-A80B-A08033C11B63 V2 EN

Figure 55:

Current measurement: Three-phase current measurement

CSMSQI1(I1,I2,I

GUID-D7B8A6D1-5D30-432A-BA7E-EFD3EEFCFF83 V2 EN

Figure 56:

Current measurement: Sequence current measurement

RESCMMXU1(Io(1)

BLOCK

HIGH_ALARM

HIGH_WARN

GUID-E920C019-B93B-42E2-8AF5-3095829351AE V2 EN

Figure 57:

Current measurement: Residual current measurement

VMMXU1

BLOCK

HIGH_ALARM

HIGH_WARN

LOW_WARN

LOW_ALARM

GUID-C56D56FD-91C3-4C7F-95D2-E11ADC494AF1 V2 EN

Figure 58:

Voltage measurement: Three-phase voltage measurement

(Terminal side)

Section 3

1MRS758272 B

REG615 standard configurations

60

REG615

Application Manual

Summary of Contents for Relion 615 series

Page 1: ...RELION 615 SERIES Generator and Interconnection Protection REG615 Application Manual...

Page 2: ......

Page 3: ...Document ID 1MRS758272 Issued 2018 12 20 Revision B Product version 5 0 FP1 Copyright 2018 ABB All rights reserved...

Page 4: ...bed in this document is furnished under a license and may be used copied or disclosed only in accordance with the terms of such license Trademarks ABB and Relion are registered trademarks of the ABB G...

Page 5: ...ted and communicate data and information via a network interface which should be connected to a secure network It is the sole responsibility of the person or entity responsible for network administrat...

Page 6: ...d concerning electrical equipment for use within specified voltage limits Low voltage directive 2006 95 EC This conformity is the result of tests conducted by ABB in accordance with the product standa...

Page 7: ...kage version 13 Operation functionality 14 Optional functions 14 Physical hardware 14 Local HMI 16 Display 17 LEDs 18 Keypad 18 Web HMI 19 Authorization 20 Audit trail 21 Communication 23 Self healing...

Page 8: ...g 87 Functional diagrams for control and interlocking 89 Functional diagram for measurement functions 91 Functional diagrams for IOs and alarm LEDs 94 Functional diagram for other timer logics 98 Othe...

Page 9: ...lay s physical connections 137 Inputs 137 Energizing inputs 137 Phase currents 137 Residual current 137 Phase voltages 137 Residual voltage 138 Auxiliary supply voltage input 138 Binary inputs 138 Opt...

Page 10: ...4...

Page 11: ...be used The manual can also be used when calculating settings 1 2 Intended audience This manual addresses the protection and control engineer responsible for planning pre engineering and engineering T...

Page 12: ...50 engineering guide Point list manual Cyber security deployment guideline GUID 12DC16B2 2DC1 48DF 8734 0C8B7116124C V2 EN Figure 1 The intended use of documents during the product life cycle Product...

Page 13: ...ectrical shock The warning icon indicates the presence of a hazard which could result in personal injury The caution icon indicates important information or warning related to the concept discussed in...

Page 14: ...d data names are shown in Courier font When the function starts the START output is set to TRUE This document assumes that the parameter setting visibility is Advanced 1 4 3 Functions codes and symbol...

Page 15: ...2 2 47O 2 Frequency protection FRPFRQ1 f f df dt 1 81 1 FRPFRQ2 f f df dt 2 81 2 FRPFRQ3 f f df dt 3 81 3 FRPFRQ4 f f df dt 4 81 4 FRPFRQ5 f f df dt 5 81 5 FRPFRQ6 f f df dt 6 81 6 Overexcitation prot...

Page 16: ...ection H3EFPSEF1 dUo Uo3H 1 27 59THD 1 Underpower protection DUPPDPR1 P 1 32U 1 DUPPDPR2 P 2 32U 2 Reverse power directional overpower protection DOPPDPR1 P Q 1 32R 32O 1 DOPPDPR2 P Q 2 32R 32O 2 DOPP...

Page 17: ...TCM 1 TCSSCBR2 TCS 2 TCM 2 Current circuit supervision CCSPVC1 MCS 3I 1 MCS 3I 1 Fuse failure supervision SEQSPVC1 FUSEF 1 60 1 Runtime counter for machines and devices MDSOPT1 OPTS 1 OPTM 1 Measurem...

Page 18: ...s instance 2 PTGAPC2 PT 2 PT 2 Time delay off 8 pcs TOFGAPC1 TOF 1 TOF 1 TOFGAPC2 TOF 2 TOF 2 TOFGAPC3 TOF 3 TOF 3 TOFGAPC4 TOF 4 TOF 4 Time delay on 8 pcs TONGAPC1 TON 1 TON 1 TONGAPC2 TON 2 TON 2 TO...

Page 19: ...ion and interoperability between substation automation devices Once the standard configuration relay has been given the application specific settings it can directly be put into service The generator...

Page 20: ...oad connectivity packages from the ABB Web site http www abb com substationautomation or directly with Update Manager in PCM600 2 2 Operation functionality 2 2 1 Optional functions Arc protection Modb...

Page 21: ...ally with configurations A and D 1 reference voltage input for SECRSYN1 60 210 V Additionally with configuration C 1 residual voltage input for H3EFPSEF1 60 210 V AI RTD mA module 3 phase voltage inpu...

Page 22: ...5 12 4 PO 2 SO 3 HSO 2 1 C AE AF AG 4 5 16 4 PO 6 SO FC 4 5 16 4 PO 2 SO 3 HSO FE FF AD 4 5 12 4 PO 6 SO 2 1 FE 4 5 12 4 PO 2 SO 3 HSO 2 1 D BC BD AD 7 5 12 4 PO 6 SO FE 7 5 12 4 PO 2 SO 3 HSO BE BF...

Page 23: ...n the selected language The amount of characters and rows fitting the view depends on the character size Table 4 Small display Character size1 Rows in the view Characters per row Small mono spaced 6 1...

Page 24: ...with PCM600 and the operation mode can be selected with the LHMI WHMI or PCM600 2 4 3 Keypad The LHMI keypad contains push buttons which are used to navigate in different views or menus With the push...

Page 25: ...ection to WHMI using TLS encryption The WHMI is verified with Internet Explorer 8 0 9 0 10 0 and 11 0 WHMI is disabled by default WHMI offers several functions Programmable LEDs and event lists System...

Page 26: ...6 Authorization Four user categories have been predefined for the LHMI and the WHMI each with different rights and default passwords The default passwords in the protection relay delivered from the f...

Page 27: ...reconstruction and examination of the sequence of system and security related events and changes in the protection relay Both audit trail events and process related events can be examined and analyze...

Page 28: ...61850 8 1 MMS WHMI FTP or LHMI Logout Successful logout from IEC 61850 8 1 MMS WHMI FTP or LHMI Password change Password changed Firmware reset Reset issued by user or tool Audit overflow Too many aud...

Page 29: ...60870 5 103 Modbus and DNP3 Profibus DPV1 communication protocol is supported by using the protocol converter SPA ZC 302 Operational information and controls are available through these protocols How...

Page 30: ...s enabled in the switches Otherwise connecting the loop topology can cause problems to the network The protection relay itself does not support link down detection or RSTP The ring recovery process is...

Page 31: ...rallel to two local area networks HSR applies the PRP principle to rings and to the rings of rings to achieve cost effective redundancy Thus each device incorporates a switch element that forwards fra...

Page 32: ...le of connecting to PRP and normal networks By connecting the node directly to LAN A or LAN B as SAN By connecting the node to the protection relay s interlink port HSR HSR applies the PRP principle o...

Page 33: ...ction automation and control functions UniGear Digital switchgear concept relies on the process bus together with current and voltage sensors The process bus enables several advantages for the UniGear...

Page 34: ...the same physical Ethernet network as the IEC 61850 8 1 station bus The intended application for sampled values is sharing the measured voltages from one 615 series protection relay to other devices...

Page 35: ...ith IEEE 1588 v2 support COM0031 COM0037 However RED615 supports this option only with the communication card variant having fiber optic station bus ports See the IEC 61850 engineering guide for detai...

Page 36: ...30...

Page 37: ...gurations Description Std conf Interconnection protection for distributed power generation A Generator protection with 100 stator earth fault protection C Generator protection with generator different...

Page 38: ...l reactive power undervoltage protection DQPTUV 1 Low voltage ride through protection LVRTPTUV 3 Voltage vector shift protection VVSPPAM 1 Power quality Current total demand distortion CMHAI 1 4 1 4 1...

Page 39: ...ARCSARC is connected in the configuration to the corresponding master trip input 4 Power quality option includes current total demand distortion voltage total harmonic distortion voltage variation an...

Page 40: ...t are not met using external auxiliary relays should be considered 3 2 Connection diagrams GUID 98367A80 8367 4836 ADD8 5EBBF8A256F4 V1 EN Figure 11 Connection diagram for the A configuration Section...

Page 41: ...GUID 7CB6E1B4 6F0D 4E22 82C7 CD9C1CECFA58 V1 EN Figure 12 Connection diagram for the C configuration 1MRS758272 B Section 3 REG615 standard configurations REG615 35 Application Manual...

Page 42: ...GUID 353BD8E6 D70E 4B5F A48D 61FAD7450715 V1 EN Figure 13 Connection diagram for the D configuration Section 3 1MRS758272 B REG615 standard configurations 36 REG615 Application Manual...

Page 43: ...ion functions must be added with the Application Configuration tool To ensure the performance of the relay the user specific configuration load is verified with the Application Configuration tool in P...

Page 44: ...P3 Interfaces Ethernet TX RJ45 FX LC Serial Serial glass ber ST RS 485 RS 232 Redundant protocols HSR PRP RSTP CONDITION MONITORING AND SUPERVISION OR AND 2 Object Ctrl 2 Ind 3 CB DC ES 1 Check availa...

Page 45: ...ip to upstream breaker X100 SO1 General protection start indication X100 SO2 General protection operate indication X100 PO3 Circuit breaker open command trip 1 X100 PO4 Circuit breaker open command tr...

Page 46: ...evel trigger mode 1 PHIPTOC1 start Positive or Rising 2 DPHLPDOC1 start Positive or Rising 3 DPHLPDOC2 start Positive or Rising 4 DPHHPDOC1 start Positive or Rising 5 EFHPTOC1 start Positive or Rising...

Page 47: ...Rising 29 PHIPTOV1 operate Level trigger off DPHLPDOC1 operate DPHLPDOC2 operate DPHHPDOC1 operate 30 EFHPTOC1 operate Level trigger off 31 PHPTOV1 operate Level trigger off PHPTOV2 operate 32 NSPTOC1...

Page 48: ...nt function blocks inside the protection relay s standard configuration However the 12 analog channels available for the disturbance recorder function are freely selectable as a part of the disturbanc...

Page 49: ...585 V2 EN Figure 15 Overcurrent protection function DPHHPDOC1 3I BLOCK ENA_MULT NON_DIR OPERATE START DPHLPDOC1 3I BLOCK ENA_MULT NON_DIR OPERATE START DPHLPDOC2 3I BLOCK ENA_MULT NON_DIR OPERATE STAR...

Page 50: ...HPTOC1_OPERATE EFHPTOC1_START CCSPVC1_FAIL GUID EC5E7304 8DB0 4CF2 B4BA E3C72DB8FF25 V2 EN Figure 19 Earth fault protection function Three phase thermal protection for feeders cables and distribution...

Page 51: ...T GUID C53EDBAE 9237 4FF3 A053 FE0647781159 V2 EN Figure 21 Circuit breaker failure protection function Three arc protection ARCSARC1 3 stages are included as an optional function The arc protection o...

Page 52: ...C3_TRIP TRPPTRC4_TRIP TRPPTRC5_TRIP X120_BI3_RST_LOCKOUT X120_BI3_RST_LOCKOUT X120_BI3_RST_LOCKOUT ARCSARC1_OPERATE ARCSARC2_OPERATE ARCSARC3_OPERATE GUID 7FC9DED3 9F34 419D 9940 F19C5644B9E0 V2 EN Fi...

Page 53: ...2F93 C2FA 4778 8E1D 0951D0D42F7C V2 EN Figure 25 Undervoltage protection function Residual overvoltage protection ROVPTOV provides earth fault protection by detecting an abnormal level of residual vol...

Page 54: ...E1ED19B V2 EN Figure 28 Positive sequence undervoltage protection function The selectable underfrequency or overfrequency or rate of change of frequency protection FRPFRQ prevents damage to the networ...

Page 55: ...supplying power into the grid DOPPDPR1 P Q BLOCK OPERATE START DOPPDPR2 P Q BLOCK OPERATE START OR B1 B2 O DOPPDPR1_OPERATE DOPPDPR1_OPERATE DOPPDPR2_OPERATE DOPPDPR2_OPERATE DOPPDPR1_START DOPPDPR2_...

Page 56: ...START OR6 B1 B2 B3 B4 B5 B6 O LVRTPTUV1_OPERATE LVRTPTUV1_OPERATE LVRTPTUV2_OPERATE LVRTPTUV2_OPERATE LVRTPTUV3_OPERATE LVRTPTUV3_OPERATE LVRTPTUV1_START LVRTPTUV2_START LVRTPTUV3_START SEQSPVC1_FUSE...

Page 57: ...START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START NSPTOC1_START NSPTOC1_START NSPTOC2_START NSPTOC2_START PHIPTOC1_START DPHLPDOC1_START DPHLPDOC2_START DPHHPDOC1_START PSPTUV1_START PSPTUV2_START NSPTO...

Page 58: ...ATE PHIPTOC1_OPERATE DPHHPDOC1_OPERATE DPHLPDOC1_OPERATE DPHLPDOC2_OPERATE PHPTOV2_OPERATE PHPTOV1_OPERATE FRPFRQ1_OPERATE FRPFRQ4_OPERATE FRPFRQ3_OPERATE PSPTUV1_OPERATE PSPTUV2_OPERATE NSPTOV1_OPERA...

Page 59: ...TE NSPTOV2_OPERATE LVRTPTUV1_OPERATE LVRTPTUV2_OPERATE LVRTPTUV3_OPERATE VVSPPAM1_OPERATE DQPTUV1_OPERATE DOPPDPR1_OPERATE DOPPDPR2_OPERATE EFHPTOC1_OPERATE ROVPTOV1_OPERATE ROVPTOV2_OPERATE PHPTUV1_O...

Page 60: ...RQ2_START FRPFRQ3_START FRPFRQ4_START NSPTOC1_START NSPTOC2_START PHIPTOC1_START DPHLPDOC1_START DPHLPDOC2_START DPHHPDOC1_START PSPTUV1_START PSPTUV2_START NSPTOV1_START NSPTOV2_START T1PTTR1_START E...

Page 61: ...DISCHARGED SSCBR1_SPR_CHR_ALM SSCBR1_OPR_ALM SSCBR1_OPR_LO SSCBR1_CB_LIFE_ALM SSCBR1_PRES_ALM SSCBR1_PRES_LO X120_BI2_CB_SPRING_CHARGED X120_BI1_GAS_PRESSURE_ALARM GUID 08A36989 C250 4568 9809 78F8DF1...

Page 62: ...supervision 3 3 3 4 Functional diagrams for control and interlocking The main purpose of the synchronism and energizing check SECRSYN is to provide control over the closing of the circuit breakers in...

Page 63: ...connector control logic ESSXSWI1 I O POSOPEN POSCLOSE OPENPOS CLOSEPOS OKPOS ESSXSWI1_OPENPOS X110_BI6_ES1_OPENED X110_BI5_ES1_CLOSED GUID B1B96FFE 6504 4373 9143 0C9FD8B804B8 V2 EN Figure 47 Earth sw...

Page 64: ...V2 EN Figure 48 Circuit breaker 1 control logic OR B1 B2 O CB_CLOSE_COMMAND CBXCBR1_EXE_CL GUID F56A6CCD 63A7 46DE A278 577732873C08 V2 EN Figure 49 Signal for closing coil of circuit breaker 1 OR6 B...

Page 65: ...AL CONTROL_REMOTE CBXCBR1_AU_CLOSE GUID 6B6BCEDB 7309 4BED BEE2 66CCC4FDDB61 V2 EN Figure 53 External closing command for circuit breaker 1 AND B1 B2 O AND B1 B2 O OR B1 B2 O FALSE FALSE CONTROL_LOCAL...

Page 66: ...surement FMMXU1 of the power system and three phase power and energy measurement PEMMXU1 are available Load profile record LDPRLRC1 is included in the measurements sheet LDPRLRC1 offers the ability to...

Page 67: ...ent Residual voltage measurement FMMXU1 GUID BF3E65A6 5F2D 43A2 8E9A F8F068A38154 V2 EN Figure 62 Other measurement Frequency measurement PEMMXU1 RSTACM GUID 1200033A FF93 4313 822D 38D4015F567E V2 EN...

Page 68: ...t 4 X110 BIO H _110 X110 Input 2 X110 BIO _110 X110 Input 2 X110 BIO H _110 X110 Input 6 X110 BIO H _110 X110 Input 7 X110 BIO _110 X110 Input 7 X110 BIO _110 X110 Input 6 X110 BIO H _110 X110 Input 3...

Page 69: ...efault binary output X100 TRPPTRC3_TRIP TRPPTRC4_TRIP TRPPTRC5_TRIP VOLTAGE_AND_FREQ_OPERATE_PULSE OC_OPERATE_PULSE EF_OPERATE_PULSE INTERCONNECTED_OPERATE_PULSE X110 BIO H _110 X110 HSO1 X110 BIO H _...

Page 70: ...B2 O AND B1 B2 O OR B1 B2 O X110_BI8_CB_OPENED SECRSYN1_SYNC_OK PHIPTOC1_OPERATE VVSPPAM1_OPERATE DQPTUV1_OPERATE EFHPTOC1_OPERATE DPHxPDOC_OPERATE LVRTPTUV_OPERATE ROVPTOV_OPERATE DOPPDPR_OPERATE GU...

Page 71: ...D_TRIGGERED ARC_OPERATE CCSPVC1_ALARM GUID F899289E 7F2D 4670 B650 5BDAC9FE20DA V2 EN Figure 70 Default LED connection 3 3 3 7 Functional diagram for other timer logics The configuration includes the...

Page 72: ...C power quality function two more instances of frequency protection and different types of timers and control functions These functions are not included in application configuration but they can be ad...

Page 73: ...pf f Limit value supervision Load pro le record RTD mA measurement optional Symmetrical components Frequency adaptivity 4 5 Analog interface types 1 Current transformer Voltage transformer 1 Conventio...

Page 74: ...nal trip 1 X130 BI2 External trip 2 X130 BI3 Lockout reset X130 BI4 Field excitation open indication Table 17 Default connections for binary outputs Binary output Description X100 PO1 Generator circui...

Page 75: ...ed 3 4 2 2 Default disturbance recorder settings Table 19 Default disturbance recorder analog channels Channel Description 1 IL1 2 IL2 3 IL3 4 Io 5 Uo 6 U1 7 U2 8 U3 9 UoB 10 11 12 Table 20 Default di...

Page 76: ...ROVPTOV2 start Positive or Rising 25 NSPTOV1 start Positive or Rising 26 NSPTOV2 start Positive or Rising 27 PSPTUV1 start Positive or Rising 28 PSPTUV2 start Positive or Rising 29 DUPPDPR1 start Pos...

Page 77: ...igger off 49 DUPPDPR1 operate Level trigger off DUPPDPR2 operate DOPPDPR1 operate DOPPDPR2 operate DOPPDPR2 operate 50 T2PTTR1 operate Level trigger off 51 SEQSPVC1 fusef 3ph Level trigger off 52 SEQS...

Page 78: ...setting groups which can be set based on individual needs Each group can be activated or deactivated using the setting group settings available in the protection relay Depending on the communication p...

Page 79: ...e 75 Voltage dependent overcurrent protection function The output BLK2H of three phase inrush detector INRPHAR1 either blocks the function or multiplies the active settings for any of the available ov...

Page 80: ...e offered for providing primary and backup protection for generator earth fault protection Transient intermittent earth fault protection INTRPTEF is used for transient based earth fault protection DEF...

Page 81: ...T2PTTR1 BLOCK AMB_TEMP OPERATE START ALARM BLK_CLOSE T2PTTR1_START T2PTTR1_OPERATE GUID C253628A 3CC5 4868 AAB6 8B563DC52AEB V2 EN Figure 81 Thermal overcurrent protection function Circuit breaker fa...

Page 82: ...nt check The operating signals from ARCSARC1 3 are connected to both generator circuit breaker trip logic TRPPTRC1 and TRPPTRC2 and also to field excitation circuit breaker trip logic TRPPTRC6 If the...

Page 83: ...ge conditions that arise due to load rejection or transient surges in the network or when a generator is running but not connected to a system due to a fault with AVR Similarly two three phase undervo...

Page 84: ...use failure function The fuse failure activation is connected to block undervoltage protection functions and voltage based unbalance protection functions to avoid faulty tripping In addition undervolt...

Page 85: ...B 485A B94D 5051B110C860 V2 EN Figure 89 Residual overvoltage protection function The selectable underfrequency or overfrequency or rate of change of frequency protection FRPFRQ prevents damage to net...

Page 86: ...ERATE FRPFRQ3_OPERATE FRPFRQ3_OPERATE FRPFRQ1_OPERATE FRPFRQ1_OPERATE FRPFRQ1_START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START BLOCK_FREQ BLOCK_FREQ BLOCK_FREQ BLOCK_FREQ FREQUENCY_OPERATE GUID 0E0FBEC...

Page 87: ...CK DISABLE OPERATE START DUPPDPR2 BLOCK DISABLE OPERATE START OR B1 B2 O DUPPDPR1_OPERATE DUPPDPR1_OPERATE DUPPDPR2_OPERATE DUPPDPR2_OPERATE DUPPDPR1_START DUPPDPR2_START SEQSPVC1_FUSEF_U SEQSPVC1_FUS...

Page 88: ...on Due to overexciation saturation of the magnetic core of generator and connected transformer may occur and stray flux may be induced in nonlaminated components that are not designed to carry flux Ex...

Page 89: ...SPTUV1_OPERATE PHPTUV1_START PHPTUV2_START PHPTOV1_START PHPTOV2_START FRPFRQ1_START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START MNSPTOC1_START MNSPTOC2_START OEPVPH1_START UZPDIS1_START H3EFPSEF1_START...

Page 90: ...OVPTOV2_OPERATE PHPTUV2_OPERATE PHPTOV1_OPERATE PHPTOV2_OPERATE PSPTUV2_OPERATE NSPTOV2_OPERATE FRPFRQ2_OPERATE MNSPTOC1_OPERATE MNSPTOC2_OPERATE OEPVPH1_OPERATE H3EFPSEF1_OPERATE DUPPDPR1_OPERATE DUP...

Page 91: ..._OPERATE PHPTUV2_OPERATE PHPTOV1_OPERATE PHPTOV2_OPERATE PSPTUV2_OPERATE NSPTOV2_OPERATE FRPFRQ2_OPERATE MNSPTOC1_OPERATE MNSPTOC2_OPERATE OEPVPH1_OPERATE H3EFPSEF1_OPERATE DUPPDPR1_OPERATE DUPPDPR2_O...

Page 92: ...PDPR1_OPERATE DOPPDPR2_OPERATE DOPPDPR3_OPERATE ARCSARC1_OPERATE ARCSARC2_OPERATE ARCSARC3_OPERATE GUID BBE9C4CA E5E3 4BE2 A00E ABCCCE0F4FC9 V2 EN Figure 99 Trip logic TRPPTRC6 Field excitation 3 4 3...

Page 93: ...PHPTUV1_OPERATE NSPTOV1_OPERATE PSPTUV1_OPERATE PHPTUV1_START PHPTUV2_START PHPTOV1_START PHPTOV2_START FRPFRQ1_START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START MNSPTOC1_START MNSPTOC2_START OEPVPH1_S...

Page 94: ...SSCBR1_SPR_CHR_ALM SSCBR1_OPR_ALM SSCBR1_OPR_LO SSCBR1_CB_LIFE_ALM SSCBR1_PRES_ALM SSCBR1_PRES_LO SSCBR1_ALARMS GUID 9CA6E0DD 75C5 412E 816A 0592DD4FAA26 V2 EN Figure 103 Logic for circuit breaker mo...

Page 95: ...er is closed MDSOPT1 BLOCK POS_ACTIVE RESET ALARM WARNING X110_BI7_CB_CLOSED MDSOPT1_ALARM GUID BE2212C3 3234 4CE4 BF91 820C7D385EEC V2 EN Figure 107 Generator runtime counter 3 4 3 4 Functional diagr...

Page 96: ...the application for opening of circuit breaker CBXCBR1 POSOPEN POSCLOSE ENA_OPEN ENA_CLOSE BLK_OPEN BLK_CLOSE AU_OPEN AU_CLOSE TRIP SYNC_OK SYNC_ITL_BYP SELECTED EXE_OP EXE_CL OP_REQ CL_REQ OPENPOS C...

Page 97: ...ee phase voltage input as well as residual voltages are connected to the X130 card in the back panel The sequence voltage measurement VSMSQI1 measures the sequence voltage The measurements can be seen...

Page 98: ...U1 BLOCK HIGH_ALARM HIGH_WARN GUID 915B8EDA 2F27 43E3 8671 49CB8A7C5279 V2 EN Figure 118 Voltage measurement Residual voltage measurement Terminal side RESVMMXU2 BLOCK HIGH_ALARM HIGH_WARN GUID ACFD93...

Page 99: ...V2 EN Figure 122 Other measurement Data monitoring LDPRLRC1 RSTMEM MEM_WARN MEM_ALARM GUID 98F5BB14 5D85 4061 83F8 71D79D53ED71 V2 EN Figure 123 Other measurement Load profile record 1MRS758272 B Sect...

Page 100: ...X110 BIO _110 X110 Input 4 X110 BIO H _110 X110 Input 8 X110 BIO _110 X110 Input 7 X110 BIO H _110 X110 Input 2 X110 BIO _110 X110 Input 1 X110 BIO H _110 X110 Input 3 X110 BIO H _110 X110 Input 4 X11...

Page 101: ...Default binary input X130 CB_OPEN_COMMAND GENERAL_OPERATE_PULSE PRIMEMOVER_SHUTDOWN_PULSE TRPPTRC6_TRIP_FIELD_EXCITATION TRPPTRC2_TRIP CCBRBRF1_TRBU X100 PSM _100 X100 PO1 X100 PSM _100 X100 PO2 X100...

Page 102: ...X110 BIO H _110 X110 HSO1 X110 BIO H _110 X110 HSO2 X110 BIO H _110 X110 HSO3 X110 BIO _110 X110 SO1 X110 BIO _110 X110 SO2 X110 BIO _110 X110 SO3 X110 BIO _110 X110 SO4 GUID DBF72C4E D03F 4AD9 9019...

Page 103: ...O OR6 B1 B2 B3 B4 B5 B6 O OR B1 B2 O PHPVOC1_OPERATE H3EFPSEF1_OPERATE UEXPDIS1_OPERATE UZPDIS1_OPERATE PHxPTOC_OPERATE EF_OPERATE ROVPTOV_OPERATE DOPPDPR_OPERATE DUPPDPR_OPERATE GUID 68A7B757 5A34 4D...

Page 104: ...B654F4A V2 EN Figure 129 Default LED connection 3 4 3 7 Functional diagram for other timer logics The configuration includes overcurrent operate earth fault operate voltage and frequency operate inter...

Page 105: ...B3 B4 B5 B6 O TPGAPC4 TP 4 IN1 IN2 OUT1 OUT2 OR6 B1 B2 B3 B4 B5 B6 O PRIMEMOVER_SHUTDOWN_PULSE CCBRBRF1_TRBU PHHPTOC1_OPERATE PHIPTOC1_OPERATE PHPVOC1_OPERATE DEFLPDEF2_OPERATE DEFLPDEF1_OPERATE DEFHP...

Page 106: ...tor or as backup protection for a medium size synchronous power generator Standard configuration D is not designed for using all the available functionality content in one relay at the same time Three...

Page 107: ...nagement Web HMI TCS TCM OPTS OPTM 2 FUSEF 60 CBCM CBCM CONDITION MONITORING AND SUPERVISION COMMUNICATION Protocols IEC 61850 8 1 9 2LE Modbus IEC 60870 5 103 DNP3 Interfaces Ethernet TX RJ45 FX LC S...

Page 108: ...p trip to upstream breaker X100 SO1 Prime mover shutdown X100 SO2 General protection operate indication X100 PO3 Generator circuit breaker open command trip 1 X100 PO4 Field excitation circuit breaker...

Page 109: ...Level trigger mode 1 PHLPTOC1 start Positive or Rising 2 PHHPTOC1 start Positive or Rising 3 PHIPTOC2 start Positive or Rising 4 PHPVOC1 start Positive or Rising 8 DEFLPDEF1 start Positive or Rising...

Page 110: ...1 operate Level trigger off MNSPTOC2 operate 42 DUPPDPR1 operate Level trigger off DUPPDPR2 operate DOPPDPR1 operate DOPPDPR2 operate 43 OEPVPH1 operate Level trigger off 45 UEXPDIS1 operate Level tri...

Page 111: ...ase currents to the protection relay are fed from a current transformer The common signal marked with 3I represents the three phase currents of the neutral side of the generator and 3IB represents the...

Page 112: ...START PHLPTOC1 BLOCK ENA_MULT OPERATE START PHHPTOC1 BLOCK ENA_MULT OPERATE START OR6 B1 B2 B3 B4 B5 B6 O PHLPTOC1_OPERATE PHLPTOC1_OPERATE PHHPTOC1_OPERATE PHHPTOC1_OPERATE PHIPTOC1_OPERATE PHIPTOC1...

Page 113: ...EN Figure 140 Negative sequence overcurrent protection function One non directional sensitive earth fault stage EFHPTOC1 and three directional earth fault stages DEFxPDEF are offered for providing pr...

Page 114: ...n provides an operating signal The operating signal is connected to the master trip 1 and 2 trip of field excitation and also to the alarm LED 1 MPDIF1 BLOCK BLK_OPR_LS BLK_OPR_HS OPERATE OPR_LS OPR_H...

Page 115: ...l current check The operating signals from ARCSARC1 3 are connected to both generator circuit breaker trip logic TRPPTRC1 and TRPPTRC2 and also to field excitation circuit breaker trip logic TRPPTRC6...

Page 116: ...OV2_START ROVPTOV_OPERATE GUID C2944708 E995 4BD7 B611 6CAC4BD0847E V2 EN Figure 148 Residual overvoltage protection function The selectable underfrequency or overfrequency or rate of change of freque...

Page 117: ...ERATE FRPFRQ3_OPERATE FRPFRQ3_OPERATE FRPFRQ1_OPERATE FRPFRQ1_OPERATE FRPFRQ1_START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START BLOCK_FREQ BLOCK_FREQ BLOCK_FREQ BLOCK_FREQ FREQUENCY_OPERATE GUID 005B0A0...

Page 118: ...DUPPDPR2_START SEQSPVC1_FUSEF_U SEQSPVC1_FUSEF_U CB_NOT_CLOSED CB_NOT_CLOSED DUPPDPR_OPERATE GUID 8E7C906F A069 46E9 AC86 DAF689BC8F03 V2 EN Figure 151 Directional underpower protection function On lo...

Page 119: ...sive voltage between laminations causing overheating and damage to insulation OEPVPH1 BLOCK OPERATE START BLK_RESTART COOL_ACTIVE OEPVPH1_OPERATE OEPVPH1_START SEQSPVC1_FUSEF_U GUID 151F93B0 B003 4817...

Page 120: ...PDEF1_START EFHPTOC1_START ROVPTOV1_START ROVPTOV2_START FRPFRQ1_START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START MNSPTOC1_START MNSPTOC2_START OEPVPH1_START DEFLPDEF1_START T2PTTR1_START UEXPDIS1_STAR...

Page 121: ...E PHIPTOC1_OPERATE PHPVOC1_OPERATE DEFLPDEF2_OPERATE DEFLPDEF1_OPERATE DEFHPDEF1_OPERATE EFHPTOC1_OPERATE ROVPTOV1_OPERATE ROVPTOV2_OPERATE MNSPTOC1_OPERATE MNSPTOC2_OPERATE DUPPDPR1_OPERATE DUPPDPR2_...

Page 122: ...PERATE ROVPTOV1_OPERATE ROVPTOV2_OPERATE MNSPTOC1_OPERATE MNSPTOC2_OPERATE DUPPDPR1_OPERATE DUPPDPR2_OPERATE X130_BI3_RST_LOCKOUT DOPPDPR1_OPERATE DOPPDPR2_OPERATE UEXPDIS1_OPERATE MPDIF1_OPERATE FRPF...

Page 123: ...OPERATE OEPVPH1_OPERATE ARCSARC1_OPERATE ARCSARC2_OPERATE ARCSARC3_OPERATE GUID D70DED0B 5023 4822 9857 94E456C3AABD V1 EN Figure 157 Trip logic TRPPTRC6 Field excitation 3 5 3 2 Functional diagrams f...

Page 124: ...START ROVPTOV1_START ROVPTOV2_START FRPFRQ1_START FRPFRQ2_START FRPFRQ3_START FRPFRQ4_START MNSPTOC1_START MNSPTOC2_START OEPVPH1_START DEFLPDEF1_START T2PTTR1_START UEXPDIS1_START T2PTTR1_OPERATE DUP...

Page 125: ...SSCBR1_TRV_T_CL_ALM SSCBR1_IPOW_ALM SSCBR1_IPOW_LO SSCBR1_MON_ALM SSCBR1_SPR_CHR_ALM SSCBR1_OPR_ALM SSCBR1_OPR_LO SSCBR1_CB_LIFE_ALM SSCBR1_PRES_ALM SSCBR1_PRES_LO SSCBR1_ALARMS GUID 5F45857B F5B3 45...

Page 126: ...the total number of generator running hours and is incremented when the energizing circuit breaker is closed MDSOPT1 BLOCK POS_ACTIVE RESET ALARM WARNING X110_BI7_CB_CLOSED MDSOPT1_ALARM GUID 1E56C486...

Page 127: ...ne side earthing switch status information is connected to DCSXSWI1 and ESSXSI1 DCSXSWI1 POSOPEN POSCLOSE OPENPOS CLOSEPOS OKPOS X110_BI4_CB_TRUCK_IN_TEST X110_BI3_CB_TRUCK_IN_SERVICE GUID 274D93AD 13...

Page 128: ...circuit breaker external opening command with the relay in local or remote mode Connect additional signals for opening of circuit breaker in local or remote mode if applicable for the configuration A...

Page 129: ...equency measurement FMMXU1 of the power system and three phase power and energy measurement PEMMXU1 are available Load profile record LDPRLRC1 is included in the measurements sheet LDPRLRC1 offers the...

Page 130: ...measurement Sequence voltage measurement RESVMMXU1 BLOCK HIGH_ALARM HIGH_WARN GUID 836F9B73 114A 42E9 BB79 31E1AE3D4B5E V2 EN Figure 178 Voltage measurement Residual voltage measurement FMMXU1 GUID E...

Page 131: ...I2_BUSBARL_VT_MCB_OPEN X110 BIO _110 X110 Input 2 X110 BIO H _110 X110 Input 4 X110 BIO H _110 X110 Input 7 X110 BIO H _110 X110 Input 1 X110 BIO _110 X110 Input 7 X110 BIO _110 X110 Input 3 X110 BIO...

Page 132: ...Default binary input X130 CB_OPEN_COMMAND GENERAL_OPERATE_PULSE PRIMEMOVER_SHUTDOWN_PULSE TRPPTRC6_TRIP_FIELD_EXCITATION TRPPTRC2_TRIP CCBRBRF1_TRBU X100 PSM _100 X100 PO1 X100 PSM _100 X100 PO2 X100...

Page 133: ...10 BIO H _110 X110 HSO1 X110 BIO H _110 X110 HSO2 X110 BIO H _110 X110 HSO3 X110 BIO _110 X110 SO1 X110 BIO _110 X110 SO2 X110 BIO _110 X110 SO3 X110 BIO _110 X110 SO4 GUID 1D844883 78D6 4C59 99AF 79C...

Page 134: ...B5 B6 O OR B1 B2 O AND B1 B2 O OR B1 B2 O SECRSYN1_SYNC_OK X110_BI8_CB_OPENED PHPVOC1_OPERATE MPDIF1_OPERATE EF_OPERATE ROVPTOV_OPERATE DOPPDPR_OPERATE DUPPDPR_OPERATE PHxPTOC_OPERATE GUID C39D654F 2B...

Page 135: ...ation includes differential operate frequency operate thermal and negative sequence protection operate prime mover shutdown logic blocking logic for frequency protection and logic to disable direction...

Page 136: ...EE478D0F V2 EN Figure 190 Timer logic for primemover shutdown pulse AND B1 B2 O X110_BI8_CB_OPENED X110_BI3_CB_TRUCK_IN_SERVICE BLOCK_FREQ GUID 062E61C6 6435 4749 AAFF 77317ED73F6B V2 EN Figure 191 Bl...

Page 137: ...included in the application configuration but they can be added based on the system requirements 1MRS758272 B Section 3 REG615 standard configurations REG615 131 Application Manual...

Page 138: ...132...

Page 139: ...current transformer of type 5P10 has the accuracy class 5P and the accuracy limit factor 10 For protective current transformers the accuracy class is designed by the highest permissible percentage co...

Page 140: ...h Fa of at least 20 The nominal primary current I1n should be chosen in such a way that the thermal and dynamic strength of the current measuring input of the protection relay is not exceeded This is...

Page 141: ...e current is only slightly higher than the starting current This depends on the accuracy limit factor of the CT on the remanence flux of the core of the CT and on the operate time setting With inverse...

Page 142: ...addition the start current settings have to be defined so that the protection relay operates with the minimum fault current and it does not operate with the maximum load current The settings for all...

Page 143: ...tion D Terminal Description X120 1 2 IL1B X120 3 4 IL2B X120 5 6 IL3B X120 7 8 IL1 X120 9 10 IL2 X120 11 12 IL3 5 1 1 2 Residual current Table 29 Residual current input included in configurations A C...

Page 144: ...range AC DC or DC is marked on the top of the LHMI of the protection relay Table 33 Auxiliary voltage supply Terminal Description X100 1 Input X100 2 Input 5 1 3 Binary inputs The binary inputs can b...

Page 145: ...0 3 BI3 X110 5 BI3 X110 4 BI4 X110 5 BI4 X110 6 BI5 X110 10 BI5 X110 7 BI6 X110 10 BI6 X110 8 BI7 X110 10 BI7 X110 9 BI8 X110 10 BI8 Binary inputs of slot X120 are available with configurations A and...

Page 146: ...if the optional communication module with light sensor inputs has been installed If the arc protection option is selected when ordering a protection relay the light sensor inputs are included in the...

Page 147: ...ection relay On delivery from the factory the start and alarm signals from all the protection stages are routed to signalling outputs Table 40 Output contacts X100 10 14 Terminal Description X100 10 S...

Page 148: ...6 SO3 common X130 17 SO3 NO X130 18 SO3 NC 5 2 3 IRF The IRF contact functions as an output contact for the self supervision system of the protection relay Under normal operating conditions the protec...

Page 149: ...tocol originally developed by Westronic The DNP3 Users Group has the ownership of the protocol and assumes responsibility for its evolution DPC Double point control EMC Electromagnetic compatibility E...

Page 150: ...the Internet is assigned a unique IP address that specifies the location for the TCP IP protocol IRIG B Inter Range Instrumentation Group s time code format B LAN Local area network LCD Liquid crysta...

Page 151: ...tation for representing a three phase power system Instead of representing each of three phases with a separate line or terminal only one conductor is represented SLD Single line diagram SMV Sampled m...

Page 152: ...146...

Page 153: ...147...

Page 154: ......

Page 155: ......

Page 156: ...01 VAASA Finland Phone 358 10 22 11 ABB Distribution Automation Maneja Works Vadodara 390013 India Phone 91 265 2604386 Fax 91 265 2638922 www abb com mediumvoltage www abb com relion www abb com subs...

Reviews: