3.2.2
Functions
MCS 3I
MCS 3I
2×
3I
3I
Io
3dl>G/M
87G/87M
P<
32U
1×
2×
X<
40
2×
P>
32R/32O
1×
2×
Io>
→
67N-1
Io>
→
67N-2
3U
REMARKS
Optional
function
Function(s) not enabled by
default in preconfiguration,
can be enabled afterwards
No. of instances
enabled by default
Calculated
value
Io/Uo
2×
No. of instances not enabled
by default
in preconfiguration,
can be enabled afterwards
1×
3U<
27
2×
Io
∆
Io
CONDITION MONITORING
AND SUPERVISION
1 0 1 0 0 0 1 1 0 0 1 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
1 0 1 0 0 0 1 1 0 0 1 1 0 0 1 0 1 0 0 0 1 1 0 0 1 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
OR
AND
GENERATOR PROTECTION AND CONTROL IED
For directly connected generator set
PRE-
CONFIGURATION
PROTECTION
LOCAL HMI *
)
REG630
COMMUNICATION
Protocols:
IEC 61850-8-1
IEC 60870-5-103
DNP3
Interfaces:
Ethernet: TX (RJ45), FX (LC)
Serial:
Serial glass fiber (ST),
Serial plastic fiber
(snap-in connector)
ALSO AVAILABLE
- 5 ×
prog. push buttons on LHMI
- Disturbance and fault recorders
- IED self-supervision
- Local/Remote push button on LHMI
- Sequence event recorder
- User management
- WebHMI
3I
FUSEF
60
U<>
U<>
Uo
A
*
)
Fixed or detached LHMI is available.
I
→
O
94
CBCM
CBCM
MEASUREMENT
- I, U, Io, Uo, P, Q, E, pf, f
- Sequence current/voltage measurement
- Limit value supervision
- RTD/mA measurement (optional)
Analog interface types
B
Curr
ent transformer
7
V
oltage transformer
3
E
E
TCS
TCM
CONTROL AND INDICATION
1)
Object
Ctrl
2)
CB
2
DC
8
ES
1)
Check availability of binary inputs/outputs
fr
om technical documentation
2)
Control and indication function for
primary object
SYNC
25
OPTS
OPTM
3Ith>T/G
49T/G
MAP
MAP
Q>
→
, 3U<
32Q, 27
3I>>>
50P/51P
3I2f>
68
U1>
47O+
2×
U2>
47O-
2×
Io>
51N-1
Io>>
51N-2
16×
3I>
→
67-1
3I>>
→
67-2
2×
U/f>
24
Z<GT
21GT
Io>>>
50N/51N
U1<
47U+
2×
Io>R
64R
3dlHi>G/M
87GH/87MH
dIoHi>
87NH
3dI>T
87T
dUo(3H)>/Uo(3H)<
27/59THD
VS
78V
U<RT
27RT
2×
2×
I(U)>
51V
2×
Uo>
59G
2× 1×
df/dt>
81R
f>
81O
f<
81U
3U>
59
2×
2×
2×
2×
2×
2×
2×
3I>
51P-1
I2>G/M
46G/46M
2×
3I>/Io>BF
51BF/51NBF
1× 1×
3I>>
51P-2
1×
1×
1× 1×
2× 1×
1×
1×
1× 1×
2×
3×
GUID-73E671D3-F46A-4778-8A7E-03AAED8AAACA V1 EN
Figure 8:
Functionality overview for preconfiguration A
Section 3
1MRS757582 C
REG630 variants
26
REG630
Application Manual