Examples on how to connect, configure and set CT
inputs for most commonly used CT connections....................48
Example on how to connect a star connected two-phase
CT set to the IED....................................................................50
Example how to connect single-phase CT to the IED............ 53
Relationships between setting parameter Base Current, CT
rated primary current and minimum pickup of a protection IED.. 54
Setting of voltage channels......................................................... 55
for most commonly used VT connections.............................. 55
Examples on how to connect a two phase-to-earth
connected VT to the IED........................................................ 56
Example on how to connect a residually connected IED....... 58
Example of analogue configuration for railway applications........59
Configuration example 1 ....................................................... 60
Configuration example 2........................................................ 61
Configuration example 3........................................................ 62
Section 5 Local HMI....................................................................... 65
Display..............................................................................................66
LEDs.................................................................................................68
Keypad............................................................................................. 69
Local HMI functionality..................................................................... 71
Protection and alarm indication................................................... 71
Parameter management .............................................................72
Front communication...................................................................73
Section 6 Differential protection..................................................... 75
Low impedance restricted earth fault protection REFPDIF ............. 75
Transformer winding, solidly earthed..................................... 76
CT earthing direction.............................................................. 77
Railway specific applications for REFPDIF function...............77
Setting guidelines........................................................................ 77
Setting and configuration........................................................77
Settings.................................................................................. 78
Single-phase railway power transformer differential protection
T1PPDIF...........................................................................................78
Identification................................................................................ 78
Application...................................................................................78
Setting guidelines........................................................................ 79
Restrained and unrestrained differential protection................79
Elimination of zero sequence currents................................... 82
Table of contents
2
Railway application RER670 2.2 IEC
Application manual
Summary of Contents for RELION RER670
Page 1: ...RELION 670 SERIES Railway application RER670 Version 2 2 IEC Application manual ...
Page 2: ......
Page 22: ...16 ...
Page 48: ...42 ...
Page 70: ...64 ...
Page 80: ...74 ...
Page 100: ...94 ...
Page 210: ...204 ...
Page 364: ...358 ...
Page 384: ...378 ...
Page 468: ...462 ...
Page 494: ...488 ...
Page 504: ...498 ...
Page 505: ...499 ...