133
Table 7.-2
Setting group 2
Variable
Group/
Channel 2
(R, P)
Setting range
Default
setting
Custo-
mer's
setting
Pickup value of element 59P-
1
2S1
0.6
…
1.4
×
U
n
(VT)
1.2
×
U
n
(VT)
Operate time of element
59P-1
2S2
0.06
…
600 s
0.06 s
IDMT operation mode setting
for element 59P-1
2S3
0
…
2
0
IDMT time dial 59P-1 TD
2S4
0.05
…
2.00
0.05
Resetting time of element
59P-1
2S5
0.07...60.0 s
0.07 s
Drop-off/pick-up ratio 59P-1
D/P
2S6
0.95
…
0.99
0.97
U
1
/U
2
mode setting of
elements 59P-2 and 27P-2
2S7
0...2
0
Pickup value of element 59P-
2
2S8
0.80
…
1.60
×
U
n
(VT)
1.20
×
U
n
(VT)
Pickup value of element 47
2S9
0.05
…
1.00
×
U
n
(VT)
0.05
×
U
n
(VT)
Operate time of element
59P-2
2S10
0.05
…
600 s
0.05 s
IDMT operation mode setting
for element 59P-2
2S11
0
…
2
0
IDMT time dial 59P-2 TD
2S12
0.05
…
2.00
0.05
Pickup value of element 27P-
1
2S13
0.20
…
1.20
×
U
n
(VT)
0.20
×
U
n
(VT)
Operate time of element
27P-1
2S14
0.10
…
600 s
0.10 s
IDMT operation mode setting
for element 27P-1
2S15
0
…
1
0
IDMT time dial 27P-1
2S16
0.10
…
2.00
0.10
Resetting time of element
27P-1
2S17
0.07...60.0 s
0.07 s
Drop-off/pick-up ratio D/P<
2S18
1.01
…
1.05
1.03
Pickup value of element 27P-
2
2S19
0.20
…
1.20
×
U
n
(VT)
0.20
×
U
n
(VT)
Pickup value of element 27D
2S20
0.20
…
1.20
×
U
n
(VT)
0.20
×
U
n
(VT)
Operate time of element
27P-2
2S21
0.10
…
600 s
0.10 s
IDMT operation mode setting
for element 27P-2
2S22
0
…
1
0
IDMT time dial 27P-2 TD
2S23
0.10
…
2.00
0.10
Pickup value of element
59N-1
2S24
2.0
…
80.0% U
n
(VT)
2.0% U
n
(VT)
1MRS755972