1MRS 751107-MUM
Protection Relay
Operator’s Manual
REX 521
15
3.2.
Menu chart
The contents of the menu chart depend on the configuration of the relay. However,
the main menu structure is always preserved.
Fig. 3.2.-1
An example of a menu chart structure
HMIchart_c
2002-22-01
08:32:23.100
2002-22-01
15:10:07.100
2002-22-01
15:10:06.100
2002-22-01
15:10:05.100
etc.
etc.
etc.
etc.
IL3-A 25.0
IL2-A 25.0
Demand values
IL1-A 25.0
Configuration
Tests
Measurements
Protection
ABB
Control
Io-A 5.0
IL3-A 25.0
IL2-A 25.0
Measured values
IL1-A 25.0
Events
14 Stored
3I>> : START
L1 , L2 , L3
3I>> : TRIP
L1 , L2 , L3
3I>> : START
L1 , L2 , L3
3I>> : TRIP
L1 , L2 , L3
Io>>
Io>
3I>>>
3I>>
3I>
Protection
3I2f>
Recorded data 3
Recorded data 2
Recorded data 1
Output data
Input data
Control setting
Setting group 2
Setting group 1
3I>>
Actual settings
Control
General
I<-->O CB1
I<-->O POS
Recorded data 1
Output data
Input data
Control setting
I<-->O CB1
Actual setting
Io
DREC
Measurements
3I
Fixed pulse
= Variable pulse
Forced pulse
= Forced pulse
Event delay
= 0.200s
Phase selection
= L1, L2, L3
Demand interval
= 1 min
Threshold select
= Not in use
Test mode
= No test
Activate IRF
=Deactivate
Input states
= 001100010
Output states
= 000000
Time multiplier
= 0.05
Operate time
= 0.05s
Start current
= 0.10x In
Operation mode
= Not in use
Recorded data 1
Input data
3I
Control setting
Inputs
Tests
General
Outputs
MAIN MENU
I<-->O IND1
I<-->O IND2
Cond. monit.
TCS
CB wear
Cond. monit.
3I MCS
Recorded data1
Output data
Input data
3I MCS
Control settings
Recorded data2
Recorded data3
Operation mode
= In use
Current select.
= L1 & L2 & L3
High limit
= 12% ln
etc.
etc.
Power Quality
PQ 3Inf
Measuring mode
= Not in use
Act.Meas.mode
= Not in use
Distort. Factor
= TDD
etc.
Rated frequency
= 50.00
Select Io
= 1o, 1/5A
IL1 pu-scale
= 500A
etc.
Power Quality
GROUP MENU
SUBGROUP MENU
PARAMETER MENU
A:Maxim. values
A:Cumulat. prob.
A:Selected harm.
B:Period info
B:Maxim. values
B:Cumul. prob.
PQ 3Inf
Statistic limits
A:Period info
10 min. values
3 sec. values
Settings
B:Selected harm.
Last exceeding
Inputs/Outputs
Duration
= 0.1s
Time
08:32:23.100
Date
2002-22-01
Jump
Manual control
Input SWGRP
Input Signals
Meas. devices
Output SWGRP
Output Signals
Output relays
General
Display
Digital Inputs
Communication
Protected unit
Self-supervision
Time
Alarm LEDs
Configuration
Analog scales
etc.
etc.