1MRS751802-MUM
REX 521
43
Protection Relay
Technical Reference Manual, Standard Configurations
Fig. 3.3.3.2.-1 Block diagram of the standard configuration H03 for REX 521
CB
p
o
s
. o
p
e
n
CB
p
o
s
. c
lo
s
e
DC
p
o
s
. o
p
en
DC
p
o
s
. cl
o
s
e
ES
p
o
s.
o
p
e
n
ES
p
o
s.
c
lo
s
e
Sel
ecto
r
Ou
tpu
t SWGR
Ps
Ou
tpu
t s
ig
n
al
s
Ou
tpu
t r
e
la
y
s
Func
ti
o
n
b
lo
c
k
s
In
pu
t SWGR
Ps
In
p
u
t s
ig
n
a
ls
Di
g
ital
in
p
u
ts
Te
rm
in
a
l
c
o
n
n
ecti
o
n
*)
N
O
TE
! Th
e
t
ri
p
a
n
d
s
ta
rt
s
ign
a
ls
f
rom
t
h
e
p
rot
e
c
ti
o
n
f
u
n
c
ti
on
b
loc
ks
ar
e r
o
u
ted di
rectl
y
to
th
e au
to
-r
ecl
o
s
er
(
O
->
I)
v
ia th
e i
n
pu
t s
w
it
ch
g
ro
u
ps
o
f th
e au
to
-r
ecl
o
s
er
an
d ar
e n
o
t s
h
o
w
n
i
n
th
e di
ag
ra
m
.
In
te
rl
o
c
ki
n
g
sc
he
m
e
3I>>
3I>>>
BSOUT
Lockout
PO1
(X
4.1.12/13)
PO2
(X
4.1.14/15)
PO3
(X
4.1.17/18)
SO1
(X
4.1.8/7/6)
SO2
(X
4.1.10/11/9)
Close
RCLOSE
CLOSE
>1
1
Lockout
Lockout reset
S
Q
R
Lockout Working
HSPO1
>1
Master Trip
Open
Ropen
SHOT1
SHOT2
SHOT3
SHOT4
SHOT5
TRDUE
TDDUE
ACTIVE
O-->I Active
AR1TRIP
AR2TRIP
AR3TRIP
AR4TRIP
CBFAIL
DEFTRIP
LOCKOUT
SHOT_ALARM
O-->I Alarm 1
AR1TRIP
AR2TRIP
AR3TRIP
AR4TRIP
CBFAIL
DEFTRIP
LOCKOUT
SHOT_ALARM
CBO
Master trip
Lockout reset
Lockout reset
PQ 3Inf trig
O/C
E/F
Iub>
3Ith>
PQ 3Inf
PQ 3Unf
O-->I
O/C
E/F
Iub>
3Ith>
SYNC1
Io>-->
Io>>-->
Io>>>-->
DC1
DC2
ES1
ES2
DC2
ES2
DC1
ES1
TCS BS
CBO
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
O-->I Ext. start
O-->I Ext. trip
O-->I
AR1
AR2
AR3
AR4
*)
I<->O CB1
Interlocking_A
Interlocking_B
Interlocking_C
Interlocking_D
Interlocking_E
CLOSEENA
&
Lockout Working
I<->O CB1
External trip
External trip
External trip
3I2f START
3I2f START
O/C
E/F
Iub>
3Ith>
PQ 3Inf
PQ 3Unf
O-->I
BS1 3I>
BS1 3I>>
BS1 3I>>>
BS1 Io>-->
BS1 Io>>-->
BS1 Io>>>-->
BS1 Iub>
BS2 3I>
BS2 3I>>
BS2 3I>>>
BS2 Io>-->
BS2 Io>>-->
BS2 Io>>>-->
BS2 Iub>
BS 3Ith>
3I>
3I>>
3I>>>
Io>-->
Io>>-->
Io>>>-->
Iub>
3Ith>
3I>
BS1
BS2
GROUP
RESET
CBFP
START
TRIP
CBFP
3I>>>
CBFP
BS1
BS2
GROUP
DOUBLE
RESET
BSOUT
START
TRIP
CBFP
GROUP
START
3I
2f
/I
1f
>
3dI/dt>
3I2f>
BS1
BS2
GROUP
RESET
START
TRIP
CBFP
Iub>
CBFP
3DI>
BLOCK
GROUP
RESET
START
TRIP
CBFP
CU_ALARM
3Ith>
CBFP
3
J>
Cab
I<->O CB1
OPEN
OPENENA
CLOSE
CLOSEENA
BINOPEN
BINCLOSE
OOPEN
OCLOSE
AOPEN
ACLOSE
3I
IL1
IL2
IL3
Io
Io
I<->O IND1
BINOPEN
BINCLOSE
I<->O IND2
BINOPEN
BINCLOSE
I<->O POS
BINLOCAL
BINREMOTE
OPEN
BINOPEN
BINCLOSE
ALARM
CB wear
ALARM
TCS1
TCSSTATE
BS
ALARM
MCS 3I
TRIGG
RESET
HAR_HIGH
CUM_HIGH
PQ 3Inf
Uo
Uo
REX 521
3I>>
CBFP
BS1
BS2
GROUP
DOUBLE
RESET
BSOUT
START
TRIP
CBFP
CBFP
Io>
BACTRL
BS1
BS2
GROUP
RESET
START
TRIP
CBFP
BACTRL
BS1
BS2
GROUP
RESET
START
TRIP
CBFP
Io>>
CBFP
BACTRL
BS1
BS2
GROUP
RESET
START
TRIP
CBFP
Io>>>
CBFP
O-->I
AR1
AR2
AR3
AR4
ARINH
CBOPEN
CBCLOSE
ON
RESET
OPEN
CLOSE
DEFTRIP
LOCKOUT
3U
UL1_U12
UL2_U23
UL3_U31
PQE
f
TRIGG
RESET
HAR_HIGH
CUM_HIGH
PQ 3Unf
ALARM
MCS 3U
SYNC
Command
SC_OK
ALARM_NC
DREC
IL1
IL2
IL3
Io
Iob
Uo
U12
U23
BI1
BI2
BI3
BI4
BI5
BI6
BI7
BI8
BI9
BI10
BI11
BI12
BI13
BI14
BI15
BI16
EXT_TRG
Start 3I>
Start 3I>>
Start 3I>>>
Start Io>-->
Start Io>>-->
Start Io>>>-->
Start Iub>
Start 3Ith>
Trip 3I>
Trip 3I>>
Trip 3I>>>
Trip Io>-->
Trip Io>>-->
Trip Io>>>-->
Trip Iub>
Trip 3Ith>
3I>
3I>>
3I>>>
Io>-->
Io>>-->
Io>>>-->
Iub>
3Ith>
3I>
3I>>
3I>>>
Io>-->
Io>>-->
Io>>>-->
Iub>
3Ith>
3I>
3I>>
3I>>>
Io>-->
Io>>-->
Io>>>-->
Iub>
3Ith>
3I>
3I>>
3I>>>
Io>-->
Io>>-->
Io>>>-->
Iub>
3Ith>
3I>
3I>>
3I>>>
Io>-->
Io>>-->
Io>>>-->
Iub>
3Ith>
Close enable
Blocking 2
DREC trig
Master trip
Logic input 1
Logic input 2
Logic input 3
Reset 2
Reset 1
Group
BACTRL
X4.2.5/6
X4.2.6/7
X4.2.8/9
X4.2.9/10
X4.2.11/12
X4.2.13/14
X4.2.15/16
X4.2.17/18
X3.1.1/2
Blocking 1
O-->I INH
O-->I ON
PQ 3Unf trig
Start 1
Start 2
I<->0 CB1 open
I<->0 CB1 close
3Ith>
MCS 3I
TCS1
PQ 3Inf har
PQ 3Inf cum
CB wear
MCS 3U
PQ 3Unf har
PQ 3Unf cum
Alarm 1
Alarm 2
O-->I Alarm 2
I<->O IND1
I<->O IND2
SWGRP
DOUBLE 3I>>
DOUBLE 3I>>>
I<->0 CB1 open
I<->0 CB1 close
3Ith>
MCS 3I
TCS1
PQ 3Inf har
PQ 3Inf cum
CB wear
MCS 3U
PQ 3Unf har
PQ 3Unf cum
Trip 2
Trip 3
CBFP
ConfH03_a
Lockout
HSPO1
(X
4.2.3/4/1/2)
>1
SWGRP
Trip 1
Close
Open
Remote
BS1 3I>
BS1 3I>>
BS1 3I>>>
BS1 Io>-->
BS1 Io>>-->
BS1 Io>>>-->
BS1 Iub>
BS2 3I>
BS2 3I>>
BS2 3I>>>
BS2 Io>-->
BS2 Io>>-->
BS2 Io>>>-->
BS2 Iub>
BS 3Ith>
3I2f START
3I2f START
3I> Start
3I> Trip
3I>> Start
3I>> Trip
3I>>> Start
3I>>> Trip
Io>-> Start
Io>-> Trip
Io>>-> Start
Io>>-> Trip
Io>>>-> Start
Io>>>-> Trip
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
MEAS HI ALARM
DI2
DI3
DI4
DI5
DI6
DI7
Interlocking
MEAS LO ALARM
MEAS HI ALARM
DI3
DI4
DI5
DI6
DI7
Lockout
CB wear
TCS1
MCS 3I
MCS 3U
DI5
DI6
DI7
DI8
Alarm LED1
Alarm LED2
Alarm LED3
Alarm LED4
Alarm LED5
Alarm LED6
Alarm LED7
Alarm LED8
Iub> Start
Iub> Trip
3Ith> Start
3Ith> Trip
O->I OPEN
O->I ACTIVE
O->I ALAR1
O->I ALAR2
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
Summary of Contents for REX 521
Page 1: ...Protection Relay REX 521 Technical Reference Manual Standard Configurations ...
Page 2: ......
Page 12: ...12 ...
Page 22: ...22 ...
Page 62: ...62 ...
Page 72: ...72 ...
Page 128: ...128 ...
Page 132: ...132 ...
Page 172: ...172 ...
Page 198: ...198 ...
Page 249: ......