ABB | SACE Emax 2
260 | © 2013
ABB |
1SDH001000R0002 - L7804
Putting into service and maintenance | 5 - Second level maintenance
Continued from the previous page
5. Remove the escutcheon plate of the circuit-breaker (e) by removing the screws (f) and
the protection plate (g) by removing the screw (h).
E
F
Figure 100 - Removing the escutcheon plate
G
H
Figure 101 - Removing the protection plate
Before cleaning and lubrication of the operating mechanism, you must remove the protection
release. For information about removal, see the document
, or request the
intervention of a technician ABB.