ABB | SACE Emax 2
Electronic accessories | 7 - Ekip Com Modbus RTU modules
211 | © 2017 ABB | 1SDH001330R0002 - ECN000058721 Rev. A
Connections
The modules must be mounted on the terminal box of the circuit-breaker or of the fixed part of the withdrawable
circuit-breaker, in the first free slot after the Ekip Supply module.
Information on the assembly is available on the website http://www.abb.com/abblibrary/DownloadCenter/, in
particular in the kit sheet
An example with an E2.2 circuit-breaker in fixed and withdrawable versions is provided to the side.
The following is a view of the terminal box of E1.2 and E2.2-E4.2-E6.2 circuit-breakers with the relevant wiring
diagram:
R2
R1
U2
U1
38
36
35
98
96
95
YR
M
S33
S51
YO
EKIP Supply
Trip Unit I/O
Ge-
Ge
Szc
K2
K1
W4
W3
Q4
Q3
Q2
Q1
YC
YU
YO2
RTC
I/O
TU
44
42
41
34
32
31
24
22
21
14
12
11
C12
C13
C11
C2
C3
C1
D2
D1
48
46
45
Ne
Rca
Ne-
Gzi
Szo
Szi
Gzo
Rct
Vn
V1
V2
V3
Module
Module
YO
01
H4
02
K5
04
K10
K9
94
92
H3
91
81
H2
82
K4
K8
84
74
K7
K3
H1
72
71
61
HC
62
64
54
52
51
EKIP Supply
Module
Trip Unit I/O
HC
K6
Ge-
Ge
Szc
K2
K1
W4
W3
R2
R1
Q4
Q3
Q2
Q1
YC2
YC
YU
YO2
RTC
I/O
TU
44
42
41
34
32
31
24
22
21
14
12
11
C22
C21
C12
C13
C11
C2
C3
C1
D2
D1
48
46
45
Ne
Rca
Ne-
Gzi
Szo
Szi
Gzo
Rct
Vn
V1
V2
V3
U2
U1
38
36
35
98
96
95
YR
M
S33
S51
EKIP Signalling 4K
Q5..Q10
Module
Module
HC
A4
A3
A4
S75I/5
193
2
1 XK7
XK7
194
W2
BUS 1
(A)(B)
W1
51
Ekip Co
m
Mo
db
us
R
TU
*O)
K51
COM
61
(B)
(A)
BUS 2
W1R
W2R
COM
K51
* L)
* L)
*S)
*S)
Ekip Co
m Redundan
t
RT
U
Modbus
Diagrams 51 - 61
For the communication lines (A) and (B), Belden type 3105A or equivalent cables must be used.
Further information is available on page 174, or on the website http://www.abb.com/abblibrary/
DownloadCenter/, where the wiring diagram is available
Access from the display
With the modules energized, and the Local Bus enabled, the presence of the modules on the terminal box
activates additional menus on the display.
To enable the Local Bus, you need to select "On" in the menu
Settings
-
Modules
-
Local Bus
.
The following table shows the path for accessing the configuration parameters of the modules from the
display:
Settings
…
Main frequency
Modules
Local/Remote
Local Bus
…
Ekip Com Modbus RTU
Serial address
Baudrate
Physical
protocol
Ekip Com Modbus RTU *R
(1)
…
Functions
Power Controller
…
(1)
As Ekip Com Modbus RTU.
The following table shows the configuration parameters of the modules:
Parameter Values
Default
Description
Serial
address
1… 247
• Ekip Com Modbus
RTU: 247
• Ekip Com Modbus
RTU Redundant: 246
Address to be assigned to the modules.
IMPORTANT: devices connected to
the same network must have different
addresses.
Baudrate
9600 bit/s,
19200 bit/s,
38400 bit/s
19200 bit/s
Data transmission speed
Physical
protocol
8.E,1, 8.O,1,
8.N,2, 8.N,1
8,E,1
• 8.E,1 = 8 data bits, 1 EVEN parity bit, 1 STOP bit.
• 8.O,1 = 8 data bits, 1 ODD parity bit, 1 STOP bit.
• 8.N,2 = 8 data bits, no parity bit, 2 STOP bits.
• 8.N,1 = 8 data bits, no parity bit, 1 STOP bit.
NOTE:
the modules can also be configured with the Ekip Connect software (see the chapter
“
", and the paragraph "
).
The following table shows the path from the display for accessing information on the modules:
About
Protection Unit
Circuit-breaker
Modules
…
Ekip Com Modbus RTU
Ekip Com Modbus RTU *R
…
Power Controller
The information on the modules that can be displayed includes the serial number and the software version.
Summary of Contents for SACE Emax E1.2
Page 2: ...ABB SACE Emax 2 2 2017 ABB 1SDH001330R0002 ECN000058721 Rev A ...
Page 8: ...VI 2017 ABB SACE Emax 2 1SDH001330R0002 ECN000058721 Rev A ...
Page 9: ...ABB SACE Emax 2 3 2017 ABB 1SDH001330R0002 ECN000058721 Rev A ...
Page 310: ...ABB SACE Emax 2 304 2017 ABB 1SDH001330R0002 ECN000058721 Rev A Service 1 Power Care ...