2TLC172249M0201, REV. C 2021-10-12
14
Safety-related characteristic data and Conformity
Conformity
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN ISO 14119:2013, EN ISO 13849-1:2015, EN 60947-5-
3:2013
EN ISO 13849-1
Up to PLe Category 4 (if both channels are used with a PLe control device)
EN 62061
Up to SIL3 depending on system architecture
Safety data
PFH
D
2.6 x 10
-10
(1/h)
Proof test
interval
(life)
20 years
MTTF
d
866 years
Certifications
TÜV, cULus
Information with regard
to UL 508
Type 1 Enclosure
Control No: 48W5
Max. Temp: 70ºC (Plastic version), 90ºC (Stainless Steel)