SM3000
Multipoint Videographic Recorder
Appendix B – Modbus Guide
160
IM/SM3000–EN Rev. L
Channel Number
Signal
2.7
2.8
2.9
2.10
2.11
2.12
Analog input value
R
4901 and 4902
4951 and 4952
5001 and 5002
5051 and 5052
5101 and 5102
5151 and 5152
Alarm A trip
R/W
4903 and 4904
4953 and 4954
5003 and 5004
5053 and 5054
5103 and 5104
5153 and 5154
Alarm B trip
R/W
4905 and 4906
4955 and 4956
5005 and 5006
5055 and 5056
5105 and 5106
5155 and 5156
Alarm C trip
R/W
4907 and 4908
4957 and 4958
5007 and 5008
5057 and 5058
5107 and 5108
5157 and 5158
Alarm D trip
R/W
4909 and 4910
4959 and 4960
5009 and 5010
5059 and 5060
5109 and 5110
5159 and 5160
Totalizer A max. flowrate
R
4911 and 4912
4961 and 4962
5011 and 5012
5061 and 5062
5111 and 5112
5161 and 5162
Totalizer B max. flowrate
R
4913 and 4914
4963 and 4964
5013 and 5014
5063 and 5064
5113 and 5114
5163 and 5164
Totalizer A min. flowrate
R
4915 and 4916
4965 and 4966
5015 and 5016
5065 and 5066
5115 and 5116
5165 and 5166
Totalizer B min. flowrate
R
4917 and 4918
4967 and 4968
5017 and 5018
5067 and 5068
5117 and 5118
5167 and 5168
Totalizer A average flowrate
R
4919 and 4920
4969 and 4970
5019 and 5020
5069 and 5070
5119 and 5120
5169 and 5170
Totalizer B average flowrate
R
4921 and 4922
4971 and 4972
5021 and 5022
5071 and 5072
5121 and 5122
5171 and 5172
Totalizer A batch total
R
4923 to 4926
4973 to 4976
5024 and 5025
5073 to 5076
5123 to 5126
5173 to 5176
Totalizer B batch total
R
4927 to 4930
4977 to 4980
5028 and 5029
5077 to 5080
5127 to 5130
5177 to 5180
Totalizer A max. flowrate
(previous batch)
R
4931 and 4932
4981 and 4982
5031 and 5032
5081 and 5082
5131 and 5132
5181 and 5182
Totalizer B max. flowrate
(previous batch)
R
4933 and 4934
4983 and 4984
5033 and 5034
5083 and 5084
5133 and 5134
5183 and 5184
Totalizer A min. flowrate
(previous batch)
R
4935 and 4936
4985 and 4986
5035 and 5036
5085 and 5086
5135 and 5136
5185 and 5186
Totalizer B min. flowrate
(previous batch)
R
4937 and 4938
4987 and 4988
5037 and 5038
5087 and 5088
5137 and 5138
5187 and 5188
Totalizer A average flowrate
(previous batch)
R
4939 and 4940
4989 and 4990
5039 and 5040
5089 and 5090
5139 and 5140
5189 and 5190
Totalizer B average flowrate
(previous batch)
R
4941 and 4942
4391 and 4392
5041 and 5042
5091 and 5092
5141 and 5142
5191 and 5192
Totalizer A batch total
(previous batch)
R
4943 to 4946
4993 to 4996
5043 to 5046
5093 to 5096
5143 to 5146
5193 to 5196
Totalizer B batch total
(previous batch)
R
4947 to 4950
4997 to 5000
5047 to 5050
5097 to 5100
5147 to 5150
5197 to 5200
Table B.31 Registers by Channel – Process Group 2, Channels 7 to 12