TOTALISER PRESET
TOTALISER PREDET
TOTALISER WRAP
ENABLE YES
NO
TOTALISER FRONT
PANEL RESET YES
NO
TOT RESET SOURCE
TOTAL WRAP
PAPER OUT ALARM
I/P FAILURE
DIGITAL I/P
CHART SPEED
LOGIC EQN
POWER FAILURE
REAL TIME ALM
PROCESS ALARM
NONE
TOTALISER FRONT
PANEL STOP/GO YES
NO
TOT STOP/GO SOURCE
TOTAL WRAP
NONE
TOTALISER TO
CONFIGURE
…6
CONFIGURATION – ADVANCED LEVEL
Totalizer Preset Value
Set the value to which the total reverts when it is reset. Begin with the first digit
indicated by the cursor (
_
). Pressing the
key stores the digit value and
advances the cursor to the next digit.
Repeat for all digits to be set.
Totalizer Predetermined Value
Set the value required to cause a reset of the total if wrap is set on, or value at which
the totalizer is to stop counting at. Setting is as for
Totalizer Preset Value
above.
Repeat for all digits to be set.
Totalizer Wrap–around Enable
When wrap-around is enabled, the total is automatically reset to the
Preset Value
once the Predetermined Value is reached.
When wrap-around is not enabled the total stops counting when the
Predetermined Value
is reached.
Totalizer Front Panel Reset Enable
When front panel reset is enabled the flow total can be reset to the preset value
from the
Totalizer Page
– see Section 3.5.
Select
YES
to enable the reset.
Totalizer Reset Source
Select the source required to automatically activate the totalizer reset:
TOTAL WRAP
– Wrap-around of a totalizer (T1 to T6)
PAPER OUT ALARM
– End of chart reached
I/P FAILURE
– Failure of analog input (A1 to A6, B1 to B6)
DIGITAL I/P
– Active digital input (DA1 to DG3)
CHART SPEED
– Selection of chart speed (1 to 3)
LOGIC EQN
– Logic equation true (1 to 10)
POWER FAILURE
– After power failure
REAL TIME ALM
– Real time alarm on (1 or 2)
PROCESS ALARM
– Pre-defined process alarm (A to M, excluding I)
NONE
– No automatic reset required.
Totalizer Front Panel Stop/Go Enable
When front panel stop/go is enabled the flow total counter can be started and
stopped from the
Totalizer Page
– see Section 3.5.
Select
YES
to enable stop/go.
Totalizer Stop/Go Source
Select the source required to automatically stop and start the totalizer:
source active
– totalizer Go
source inactive
– totalizer Stop.
The sources are as for
Totalizer Reset Source
above.
Return to the
Totalizer to Configure
parameter.
Note.
For standard continuous counting set
Preset Value
to 00000000,
Predetermined Value
to 99999999 and wrap to
YES
.
…6.4.2
Totalizer Configuration Page