background image

 

I N S TA LL ATI O N  M A N UA L 

Stanilite®

Platinum exit LED evago

DALI emergency

Doc no. 29-00309_1

This document covers

What’s inside the box

Safety warning

Exit LED evago

Installation instructions

Installation manual

Testing precautions

Warranty information

Troubleshooting guide

Troubleshooting guide

If you have installed and connected the fitting as per the instructions listed earlier and it does 
not function correctly, use the following table as a guide to fixing the problem. Look up the 
type of fault in the left column and check the possible causes from the right column.  

If the fitting still does not work after checking these possible causes, contact ABB customer 
service in Australia on 1800 60 20 20.


ABB Australia Pty Limited

For enquiries
ABB contact centre: 1800 60 20 20
E-mail: AU-ABB-Stanilite@abb.com 

www.stanilite.com.au

© Copyright 2020 ABB. All rights reserved. 

9

A

K

K

10

70

4

6

A

0

9

78 - A - F

eb  2

0

20

No. Fault

Possible causes

1

LED light source and indicating LED not lit

AC supply not connected; 

or

AC supply turned off

2

LED light source is lit but indicating LED not lit

Battery not connected or faulty

3

LED light source does not switch to emergency 
mode when the test button is pressed

Test switch damaged; 

or

Battery not connected or faulty

4

LED light source works momentarily on emergency 
when the test button is pressed

Battery not yet charged (allow up to 24 hours)

Thank you for choosing ABB product

Please read this document thoroughly before 
commencing installation and retain for future 
reference. Contact ABB customer service in 
Australia on 1800 60 20 20 if you need any 
assistance. The installation instructions were 
correct at the time of print. To reflect changes in 
technology and Australian standards; ABB 
reserves the right to amend the instructions 
without notice. Updated document can be found 
on the Stanilite website.

Safety warning

In Australia and New Zealand, only licensed 
electricians are permitted by law to work with 
240 volt electrical installations.
Do not attempt to install or connect this product 
unless you are a licensed electrician.
Turn off and isolate the electrical supply before 
connecting this fitting to the building wires.
Do not touch the terminals of the terminal block 
when the light fitting is energised.
The only user-serviceable part is the battery 
pack. LED light source is not user-serviceable.
Do not attempt to service other parts of the 
fitting as this will void the warranty.
As the installer, it is your responsibility to ensure 

compliance with all relevant building and safety 

codes, (ie: AS/NZS 3000, AS/NZS 2293). Refer to 

the applicable standards for data and mains 
cabling installation procedures and 
requirements.

DALI (Digital Addressable Lighting Interface)

DALI is widely acknowledged as being an open 
protocol as defined under IEC 62386 and is 
designed only for communication in lighting 
systems. 
ABB exit and emergency luminaire with DALI 
functionality comply with DALI standard IEC 
62386.
The DALI evago wiring consists of additional 2 
control wires apart from the active and neutral 

wires (4 cores) in a power cord supplied with 

product.

Note: No mains or mains carrying cables are to 
be connected to DALI terminals or 2 control 
wires (white and black).

Important to note:

•  This product is designed for indoor use only.

Reviews: