I N S TA LL ATI O N M A N UA L
Stanilite®
Platinum exit LED evago
DALI emergency
Doc no. 29-00309_1
This document covers
What’s inside the box
Safety warning
Exit LED evago
Installation instructions
Installation manual
Testing precautions
Warranty information
Troubleshooting guide
Troubleshooting guide
If you have installed and connected the fitting as per the instructions listed earlier and it does
not function correctly, use the following table as a guide to fixing the problem. Look up the
type of fault in the left column and check the possible causes from the right column.
If the fitting still does not work after checking these possible causes, contact ABB customer
service in Australia on 1800 60 20 20.
—
ABB Australia Pty Limited
For enquiries
ABB contact centre: 1800 60 20 20
E-mail: AU-ABB-Stanilite@abb.com
www.stanilite.com.au
© Copyright 2020 ABB. All rights reserved.
9
A
K
K
10
70
4
6
A
0
9
78 - A - F
eb 2
0
20
No. Fault
Possible causes
1
LED light source and indicating LED not lit
AC supply not connected;
or
AC supply turned off
2
LED light source is lit but indicating LED not lit
Battery not connected or faulty
3
LED light source does not switch to emergency
mode when the test button is pressed
Test switch damaged;
or
Battery not connected or faulty
4
LED light source works momentarily on emergency
when the test button is pressed
Battery not yet charged (allow up to 24 hours)
Thank you for choosing ABB product
Please read this document thoroughly before
commencing installation and retain for future
reference. Contact ABB customer service in
Australia on 1800 60 20 20 if you need any
assistance. The installation instructions were
correct at the time of print. To reflect changes in
technology and Australian standards; ABB
reserves the right to amend the instructions
without notice. Updated document can be found
on the Stanilite website.
Safety warning
In Australia and New Zealand, only licensed
electricians are permitted by law to work with
240 volt electrical installations.
Do not attempt to install or connect this product
unless you are a licensed electrician.
Turn off and isolate the electrical supply before
connecting this fitting to the building wires.
Do not touch the terminals of the terminal block
when the light fitting is energised.
The only user-serviceable part is the battery
pack. LED light source is not user-serviceable.
Do not attempt to service other parts of the
fitting as this will void the warranty.
As the installer, it is your responsibility to ensure
compliance with all relevant building and safety
codes, (ie: AS/NZS 3000, AS/NZS 2293). Refer to
the applicable standards for data and mains
cabling installation procedures and
requirements.
DALI (Digital Addressable Lighting Interface)
DALI is widely acknowledged as being an open
protocol as defined under IEC 62386 and is
designed only for communication in lighting
systems.
ABB exit and emergency luminaire with DALI
functionality comply with DALI standard IEC
62386.
The DALI evago wiring consists of additional 2
control wires apart from the active and neutral
wires (4 cores) in a power cord supplied with
product.
Note: No mains or mains carrying cables are to
be connected to DALI terminals or 2 control
wires (white and black).
Important to note:
• This product is designed for indoor use only.