Pressing "EXIT" when User Lines are being displayed will initiate a cycling display
of the selected Wakeup parameters for a period of 15 minutes and then return to the
User Lines display.
•
If no Wakeup screens are selected, then nothing will be displayed and the User Lines
will blink for a moment.
The Adapter Panel Drag Hand Reset switches only reset the Tap
position Drag Hands value.
•
While cycling is in effect, when ENT is pressed on any demand metering value ("E"
displayed on screen), all demand metering Drag Hand parameters will be reset. This
is also true for all metering Drag Hand values when ENT is pressed on an energy
metering menu.
•
The Wakeup stepped display can be stopped on the displayed parameter by pressing
EXIT. Press EXIT again to terminate the stepped parameter display and return to the
User Lines. The Wakeup screen values can be browsed by utilizing the Up and Down
arrow pushbuttons. In this mode, if the ENT pushbutton is pressed while on a demand
or energy metering value, it will only reset that individual Drag Hand value.
•
The Wake screen cycles at a 3 second interval between parameters. While the wake
screen menu is cycling, if a parameter is missed while recording, press the up arrow
to display it again. This displays the previous parameter and then continues cycling
to the next parameter 3 seconds later. Pressing ENT stops the cycling and allows the
user to utilize the Up and Down Arrows to view the Wake screen parameters at a user
defined pace.
•
When there is a Smart Flash SD Card present while in the Wakeup screen menu, an
additional Smart Flash SD Card menu item will be present. All Wakeup screen
parameters can be saved to the Smart Flash SD Card in *.csv format.
5.4.1
Selecting wakeup screen parameters
1.
Select
Setup/Wakeup Screens
from the TCC600® toolbar. TCC600 will display
the "Wakeup Screen Menu Setup" dialog screen.
1VAC388793-MB A
Section 5
System setup
TCC300
275
User Manual
Summary of Contents for TCC300
Page 1: ...Digital Tapchanger Control TCC300 User Manual ...
Page 2: ......
Page 3: ...Document ID 1VAC388793 MB Issued 2016 08 10 Revision A Copyright 2016 ABB All rights reserved ...
Page 26: ...20 ...
Page 34: ...28 ...
Page 91: ...1VAC388793 MB A Section 3 Operation TCC300 85 User Manual ...
Page 126: ...120 ...
Page 176: ...Section 4 1VAC388793 MB A TCC600 170 TCC300 User Manual ...
Page 260: ...254 ...
Page 328: ...322 ...
Page 494: ...488 ...
Page 556: ...550 ...
Page 580: ...574 ...
Page 600: ...594 ...
Page 700: ...694 ...
Page 710: ...704 ...
Page 712: ...706 ...
Page 713: ...707 ...
Page 714: ......
Page 715: ......