background image

 

 

2TLC172117M0201, rev. A 

10 

www.abb.com/lowvoltage 

2011-09-19  

6  Technical data 

Manufacturer 

Address 

ABB AB / JOKAB SAFETY 
Varlabergsvägen 11 
SE-434 39 Kungsbacka 
Sweden 

Article number/Ordering data 

Tina 1A: 2TLA020054R0000 

 

Power supply 

Operating voltage 

24 VDC +15 %, -25 % 

Total current consumption 

17 mA (27 mA with max information output) 
Information output: Max 10 mA 

Time delay t (in/out) 

t < 60 µs 

Voltage supply at normal operation (protection 
OK) and 24 VDC supply voltage 

Dynamic input: between 9 and 13 volt (RMS) 
Dynamic output: between 9 and 13 volt (RMS) 
Information output: ~ 23 VDC 

 

General 

Protection class 

IP67 

Ambient temperature 

Storage: -30…+70°C 
Operation: -10…+55°C 

Humidity range 

35 to 85 % (with no icing or condensation) 

Housing material 

PVC 

Connector 

M12 5-pole male 

Size 

47 x 25 x 15 (L x W x H) 

Weight 

~ 20 g 

Colour 

Black 

 

Safety / Harmonized Standards 

Conformity 

European Machinery Directive 2006/42/EC 

 

EN ISO 12100-1:2003, EN ISO 12100-2:2003, 
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008, 
EN 62061:2005 

IEC/EN 61508-1…7 

SIL3, PFHd: 4.50*10

-9

 

EN 62061 

SIL3 

EN ISO 13849-1 

Performance level: Pl e, category 4 

EN 954-1 

Category 4 

Certificates 

TÜV Nord 

Summary of Contents for Tina 1A

Page 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 1A Blanking plug ...

Page 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attenti...

Page 3: ...ecial notes 4 2 Overview 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troubleshooting 8 5 Operation 9 LED indication 9 6 Technical data 10 Dimensions 11 7 EC Declaration of conformity 12 ...

Page 4: ...of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment ...

Page 5: ... before using the device The devices shall be installed by a trained electrician following the Safety regulations standards and the Machine directive Failure to comply with instructions operation that is not in accordance with the use prescribed in these instructions improper installation or handling of the device can affect the safety of people and the plant For installation and prescribed use of...

Page 6: ...ors M12 C312 2TLA020056R2100 3 m cable 5 pole 0 34 mm 2 M12 female M12 male connectors 5 x 0 34 mm 2 cable screen with straight female male M12 connectors Screen connected to pin 3 0 VDC on male connector Article number 2TLA020056R2000 1 m 2TLA020056R2100 3 m M12 5 pole male seen from cable side 2 1 5 4 3 M12 5 pole female seen from cable side 1 2 5 3 4 5 pole M12 connector 1 Brown 24 VDC 2 White ...

Page 7: ...2TLC172117M0201 rev A 7 www abb com lowvoltage 2011 09 19 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables ABB ...

Page 8: ...sting of the safety functions Make sure the safety unit is working properly by following these steps Interrupt the dynamic safety circuit before this unit The LED will flash between green and red The LED will light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indicator note Expected causes of faults Checking and measures to take Li...

Page 9: ...1 09 19 5 Operation LED indication LED Indication Description Input signal on pin 2 LED on Tina Green Safety circuit closed protection OK Dynamic signal in Green Red flash Safety circuit open protection OK No dynamic signal in or 0 VDC in Red 24 VDC in ...

Page 10: ...mic input between 9 and 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connector M12 5 pole male Size 47 x 25 x 15 L x W x H Weight 20 g Colour Black Safety Harmonized Standards Conformity European Machinery D...

Page 11: ...2TLC172117M0201 rev A 11 www abb com lowvoltage 2011 09 19 Dimensions NB All measurements in millimetres ...

Page 12: ...d to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including lo...