- 100 -
UMC100-FBP
Universal Motor Controller
UMC100-FBP
Technical Description
FieldBusPlug / Issue: 03.2012
Motor Management Parameters
Within this submenu all motor management r
elated parameters can be configured. The diagram below
shows the organisation of the different parameter masks in the menu tree.
Control function
Reverse lockout time
1
YD changeover mode
2
YD starting time
2
Time limit actuator
3
Fault output
Checkback
Inching DI start input
Local ctrl mode 1
Auto ctrl mode
Local ctrl mode 2
Invert ctrl inputs
Multifunction inputs
Enable custom logic
Limt number of starts
Extended
1 Motor Management
Loc1 start bus cyc.
Loc1 stop bus cyc.
Loc1 start LCD
Loc1 stop LCD
Loc1 start bus acyc.
Loc1 stop bus acyc.
Loc1 start DI
Loc1 stop DI
1.9 Local control mode 1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.14
1.15
1.16
1.9.1
1.9.2
1.9.3
1.9.4
1.9.5
1.9.6
1.9.7
1.9.8
1) Only for control function REV
2) Only for control function YD
3) Only for control function Actuator
Loc2 start bus cyc.
Loc2 stop bus cyc.
Loc2 start LCD
Loc2 stop LCD
Loc2 start bus acyc.
Loc2 stop bus acyc.
Loc2 start DI
Loc2 stop DI
1.11 Local control mode 2
1.11.1
1.11.2
1.11.3
1.11.4
1.11.5
1.11.6
1.11.7
1.11.8
Auto start bus cyc.
Auto stop bus cyc.
Auto start LCD
Auto stop LCD
Auto start bus acyc.
Auto stop bus acyc.
Auto start DI
Auto stop DI
1.10 Auto ctrl mode
1.10.1
1.10.2
1.10.3
1.10.4
1.10.5
1.10.6
1.10.7
1.10.8
Multifunction 0
Multifunction 1
Multifunction 2
Multif. 0 delay
Multif. 1 delay
Multif. 2 delay
Multif. 0 autoreset
Multif. 1 autoreset
Multif. 2 autoreset
Multif. 0 fault text L1/2
Multif. 1 fault text L1/2
Multif. 2 fault text L1/2
1.13 Multifunction inputs
1.13.1
1.13.2
1.13.3
1.13.4
1.13.5
1.13.6
1.13.7
1.13.8
1.13.9
1.13.10
1.13.12
1.13.14
Checkback time
Emergency start
Fault auto reset
Custom app parameter
Auxiliary inputs
1.16 Extended
1.16.1
1.16.2
1.16.3
1.16.4
1.16.5
Invert DI start inp.
Invert DI stop inp.
1.12 Invert ctrl inputs
1.12.1
1.12.2
Aux inp 1 ack mode
Aux inp 1 reaction
Aux inp 1 delay
Aux inp 1 message L1
Aux inp 1 message L2
1.16.5 Auxiliary inputs
1.16.5.1
1.16.5.2
1.16.5.3
1.16.5.4
1.16.5.5
...
(Same repeats for Aux 2 ... 6)
Num starts allowed
Num starts window
Num starts pause
Num starts overrun
Num starts prewarn
1.15 Limit num of starts
1.15.1
1.15.2
1.15.3
1.15.4
1.15.5
The parameters are described in details in the section "Parameters and Data Struc-
tures on a Fieldbus->Parameter Organisation-> Motor Management Parameters". A
description of the parameters of the menu entry "Auxiliary inputs" can be found in the
section "Parameters and Data-Structures on a Fieldbus->Parameter Organization->
Function Block Related Parameters".