Primary Switch Mode Inverter
UNV-F
Operation Manual
Page 23 (28)
BHB.UNV-F.D65-1050.HB101
8.2 Connector CAN-Bus
Connector X2 (socket outlet RJ45,6pol):
Pin
Signal
CAN1
Signal-
CAN2
Name
1 CAN_V+
DC-Supply
+8...15V
2 CAN_V+
DC-Supply
+8...15V
3 CAN_H
Signal
(high)
4 CAN_L
Signal (low)
5 CAN_V-
DC-Supply
Ground
6 CAN_V-
DC-Supply
Ground
9. Maintenance
In general, the inverter is maintenance-free.
A yearly inspection with following checks is recommended:
Correct fan operation
Mechanical inspection
Removal of dust and dirt, especially on radiator surfaces
Check for internal dust or humidity
Attention! Dust together with dew or water can destroy the
internal circuits by short circuit.
Dust inside the unit can be blown out with dry compressed
air.
The intervals between these checks depends on ambient con-
ditions of the installed module.
CAN-Bus-Interface