6
V D 4 X
I N S T R U C T I O N M A N U A L
—
Technical data
2.1 Circuit-breaker VD4X
Rated voltage
Maximum operating voltage
Standards
Switchgear type
Insulating gas system
1)
Insulating gas
Alarm level for insulation (pae) at 20
°C
Rated filling level for insulation (pae) 20
°C
Electrical data
Rated power frequency withstand voltage
Rated lighting impulse withstand voltage
Voltage apply to an absolute insulating gas
pressure at 20
°C
Rated frequency
Rated current
Rated short-circuit breaking current
Rated short-circuit duration
Rated operating sequence
kV
kV
kPa
kPa
kV
kV
kPa
Hz
A
kA
s
12
12
IEC/GB
•
•
SF
6
2)
120
130
28
5)
/42
6)
75
5)
/75
6)
120
50/60
17.5
17.5
IEC
•
SF
6
2)
120
130
38
5)
95
5)
120
50/60
24
24
IEC/GB
•
•
SF
6
2)
120
130
50
5)
/65
6)
125
5)
/125
6)
120
50/60
36
36
IEC
•
•
SF
6
2)
120
130
70
5)
170
5)
120
50/60
40.5
40.5
IEC/GB
•
•
SF
6
2)
/AirPlus
3)
120
130
85
5)
/95
6)
185
5)
/185
6)
120
50/60
ZX0.2
ZX1.2
ZX2
630
7)
/1250/1600/2000/2500
25/31.5/40
8)
3
5)
/4
6)
O-0.3 s-CO-3 min-CO
Breaker
type
VD4X
…1
2
1
2
-
31
…1
22
5-
31
…1
7
1
2
-
31
…
2
41
2-3
1
…
2
4
2
5-
3
1
…
36
1
2-3
1
…
362
5-
3
1
…
362
5-40
…401
2-3
1
…40
2
5-
3
1
…40
2
5-40
Rated
Voltage
kV
12
12
17.5
24
24
36
36
36
40.5
40.5
40.5
Rated
current
A
…1
2
50
1600…2
500
…1
2
50
…1
2
50
1600…2
500
…1
2
50
…
2
500
1250…2
500
…1
2
50
…
2
500
…
2
500
Rated
short-circuit
breaking
current symm.
8)
kA
…
31.5
…
31.5
…
31.5
…
3
1.5
…
3
1.5
…
3
1.5
…
3
1.5
…40
…
3
1.5
…
3
1.5
…40
Rated
short-circuit
making current
(peak)
8)
kA
…
80
…
80
…
80
…
8
0
…
8
0
…
8
0
…
8
0
…100
…
8
0
…
8
0
…100
Rated
short-circuit
duration
s
4
4
4
4
4
4
4
4
4
4
4
Panel
width
mm
6
00
8
00
6
00
6
00
8
00
6
00
8
00
8
00
6
00
8
00
8
00
Pole
centres
mm
150
2
10
150
150
2
10
150
2
10
2
10
150
2
10
2
10
Permissible of
vacuum-interrupter
switching
operations
Figure 2/2 Page 9
Diagram A&B
Diagram A&B
Diagram A&B
Diagram A&B
Diagram A&B
Diagram A&B
Diagram A&B
Diagram C&D
Diagram A&B
Diagram A&B
Diagram C&D
1) See instruction manual in ZX-Switchgear for further details.
2) Insulaitng gas: sulphur hexafluoride.
3) Only availiable in switchgear type ZX2.
5) Comply with IEC standards.
6) Comply with GB standards.
7) Only availiable in switchgear type ZX0.2 & ZX1.2.
8) Only availiable in 40.5kV with switchgear type ZX2.
8) For operating voltage lower than rated voltage, the same values as for rated voltage always apply. Higher values on request.