ABB

5:6

Approvals:

Control of:

Entire safety system based on 
the dynamic safety circuit.

Features:

Easy installation

Flexible

Cost effective

Display for troubleshooting 
(Vital 2 and 3)

A wide range of safety sen-
sors can be connected into the 
circuit

Several safe outputs

Information output

Outputs with time delay  
(Vital 2 and 3)

TÜV Nord 

– Vital 1

TÜV Rheinland 

– Vital 2 and 3

Vital is based on a single channel safety concept where multi-
ple safety sensors can be connected in series and monitored 
with a single safety controller. A dynamic signal is sent from 
Vital through all connected sensors, and then returned to Vital 
which then evaluates the received signal. As each safety sen-
sor inverts the signal, it is possible to detect short circuits or 
faults in any of the sensors. Vital 2 and Vital 3 are designed 
for use with ABB Jokab Eden sensors, Tina components and 
Spot light grids or similar products. Vital 2 and 3 are both 
safety controllers with two safe input functions and two output 
groups, the only difference between the two models being in 
the input configuration.

Vital

Safety controller

Summary of Contents for vital 1

Page 1: ...ors can be connected in series and monitored with a single safety controller A dynamic signal is sent from Vital through all connected sensors and then returned to Vital which then evaluates the recei...

Page 2: ...monitored by one module Simple system with extensive functionality Up to 10 sensors can be connected to each dynamic safety circuit Output group 2 can be set for time delay Three different modes of o...

Page 3: ...manually supervised and automatic reset can be used Vital 1 has a switching relay output for information The function is determined by a DIP switch TheDIPswitchposition1 originalposition is the inform...

Page 4: ...00 m Maximum number of units varies depending on the installation and cable size For more information see the examples in this chapter Response time At Power on When activating input output When deact...

Page 5: ...ABB 5 10 Connection of units and cable lengths to Vital 1...

Page 6: ...6 Tina 4A units can be connected to one Vital 1 equivalent to 30 Eden Tina units with a total cable length of 600 metres 0 75 mm2 to Tina 4A Example Either 2 x 500 metre cables 0 75 mm2 from the contr...

Page 7: ...ch as Eden Tina and Spot can easily be con nected in series Up to 10 Eden or Tina devices can be con nected in series per input function Input function 2 The same function as input function 1 Output g...

Page 8: ...trols output group 2 Operating mode M2 Input 1 master function Vital 2 Input function 1 stops all outputs and input function 2 stops output group 2 Operating mode M3 Parallel function Vital 2 Input fu...

Page 9: ...put s Auto reset 1 and Auto reset 2 Connection of outputs Vital 2 4 4 9 4 4 9 4 The safe relay outputs that are duplicated in series break between 1L Q1 output group 1 and 11L Q11 output group 2 The l...

Page 10: ...ion Spot 10 1 Spot 35 3 Total max cable length depending on the number of Spot T R 100 m Maximum number of units varies depending on the installation andcable size For more information see the example...

Page 11: ...with the dynamic signal and the other with static 24 VDC Input function 2 A dynamic safety circuit where ABB Jokab Safety s safety sensors Eden Tina and Spot can easily be connected in se ries Up to 1...

Page 12: ...s output group 2 Operating mode M3 Parallel function Vital 3 Input function 1 and input function 2 operate in parallel and control all out puts Reset Auto reset 1 resets both input functions Reset Aut...

Page 13: ...by means of the input s Auto reset 1 and Auto reset 2 Connection of outputs Vital 3 4 4 9 4 4 9 4 The safe relay outputs that are duplicated in series break between 1L Q1 output group 1 and 11L Q11 ou...

Page 14: ...pot 35 3 Total max cable length depending on the number of Spot T R 100 m Maximum number of units varies depending on the installation andcable size For more information see the examples in this chapt...