ABB

5:16

Vital 3 is a safety controller that combines functionality with 
the quick and easy installation of safety sensors. With two 
safe input functions and two different output groups, Vital 3 
offers the capability to exclusively control smaller machine 
safety systems that would otherwise have required a pro-
grammable controller or multiple safety relays. How the two 
output groups are controlled by the input functions depends 
on which of the three operating modes is selected (see Selec-
tion of operating mode).

Input function 1:

A two-channel safety circuit designed for opening contacts, 
e.g.  two-channel  emergency  stop  or  ABB  Jokab  Safety's 
safety switch JSNY5. One channel is fed with the dynamic 
signal and the other with 24 VDC.

Input function 2:

A dynamic safety 

circuit

 where ABB Jokab Safety's safety 

sensors Eden, Tina and Spot can easily be connected in se-
ries. Up to 12 Eden or Tina devices can be connected in 
series per input function.

Output group 1:

A safe relay output in a duplicated series and a safe transistor 
output with output voltage of -24 VDC.

Output group 2:

A safe relay output in a duplicated series and a safe transistor 
output with output voltage of -24 VDC. In addition, output 
group 2 contains a non-safe transistor output with output 
voltage of +24 VDC, intended for information. The output 
group can have time delay from 0 to 1.5 s.

Selection of operating modes 

Vital 3 can be configured to operate in one of three operat-
ing modes M1, M2 or M3. The selection of operating modes 
is done by connecting one of the terminals M1, M2 or M3 
to +24 V.

Vital 3

Summary of Contents for vital 1

Page 1: ...ors can be connected in series and monitored with a single safety controller A dynamic signal is sent from Vital through all connected sensors and then returned to Vital which then evaluates the recei...

Page 2: ...monitored by one module Simple system with extensive functionality Up to 10 sensors can be connected to each dynamic safety circuit Output group 2 can be set for time delay Three different modes of o...

Page 3: ...manually supervised and automatic reset can be used Vital 1 has a switching relay output for information The function is determined by a DIP switch TheDIPswitchposition1 originalposition is the inform...

Page 4: ...00 m Maximum number of units varies depending on the installation and cable size For more information see the examples in this chapter Response time At Power on When activating input output When deact...

Page 5: ...ABB 5 10 Connection of units and cable lengths to Vital 1...

Page 6: ...6 Tina 4A units can be connected to one Vital 1 equivalent to 30 Eden Tina units with a total cable length of 600 metres 0 75 mm2 to Tina 4A Example Either 2 x 500 metre cables 0 75 mm2 from the contr...

Page 7: ...ch as Eden Tina and Spot can easily be con nected in series Up to 10 Eden or Tina devices can be con nected in series per input function Input function 2 The same function as input function 1 Output g...

Page 8: ...trols output group 2 Operating mode M2 Input 1 master function Vital 2 Input function 1 stops all outputs and input function 2 stops output group 2 Operating mode M3 Parallel function Vital 2 Input fu...

Page 9: ...put s Auto reset 1 and Auto reset 2 Connection of outputs Vital 2 4 4 9 4 4 9 4 The safe relay outputs that are duplicated in series break between 1L Q1 output group 1 and 11L Q11 output group 2 The l...

Page 10: ...ion Spot 10 1 Spot 35 3 Total max cable length depending on the number of Spot T R 100 m Maximum number of units varies depending on the installation andcable size For more information see the example...

Page 11: ...with the dynamic signal and the other with static 24 VDC Input function 2 A dynamic safety circuit where ABB Jokab Safety s safety sensors Eden Tina and Spot can easily be connected in se ries Up to 1...

Page 12: ...s output group 2 Operating mode M3 Parallel function Vital 3 Input function 1 and input function 2 operate in parallel and control all out puts Reset Auto reset 1 resets both input functions Reset Aut...

Page 13: ...by means of the input s Auto reset 1 and Auto reset 2 Connection of outputs Vital 3 4 4 9 4 4 9 4 The safe relay outputs that are duplicated in series break between 1L Q1 output group 1 and 11L Q11 ou...

Page 14: ...pot 35 3 Total max cable length depending on the number of Spot T R 100 m Maximum number of units varies depending on the installation andcable size For more information see the examples in this chapt...

Reviews: