7.1.7. Circuit breaker control card
N.B.
Changing the settings by means of dip-switches must be carried out with the control
module de-energised and the capacitor discharged since the selections set and/or modified
are acquired by the control electronics at the moment it is turned on.
Connector for the
storage capacitor/s
and the actuator coils
Power supply
connector
Connector for:
- closing pushbutton
- opening pushbutton
- luminous “READY” signal
Connector for input signal of
the circuit breaker
open/closed position sensors
Jumper only present in the full
option version.It is not normally
short-circuited and energy
consumption during capacitor
charging is 100 W.If it is short-
circuited, energy consumption
during capacitor charging is
reduced to 50 W (the charging time
is obviously doubled)
pos. 1-2:
trip input for
PR12 release
pos. 2-3:
standard opening
input
Presetting of the trip threshold for
the undervoltage function
Rated voltage
Setting
range
35% ... 70%
(Normally
preset to OFF)
220-240 V
AC / DC
84 V ... 154 V
AC / DC
100-127 V
AC / DC
45 V ... 70 V
AC / DC
48-60 V
DC
21 V ... 33 V
DC
24-30 V
DC
11 V ... 16 V
DC
Input connector:
-SO4
(1)
; -SL1; -SO3; -SO2; -SC2
ANSI self-pumping function
enabled
ANSI self-pumping function
disabled (normally preset)
Disabled (normally preset)
Automatic opening due to low energy of
the capacitor/s
Enabled (on request)
Enabling for closing with undervoltage function activated
Output connector:
DOR; DN; DR; DC2
(1)
;
DO2
(1)
; -DC1; DO1
Enabling for closing only after return of voltage at the undervoltage
input (the circuit breaker re-opens after the set delay time)
Enabling for closing with undervoltage function activated
(
1
) Full Option version.
(
2
) If enabled, the SO3 input behaves like a hardware input operation even when there is a
fault in the microprocessor. If disabled, the –SO3 input behaves like a digital opening
input processed by the microprocessor.
Selector not used for the VM1 circuit breaker
(the position selected does not matter)
Safety opening disabled
Safety opening
(2)
Safety opening enabled (normally
preset)
Function
disabled(normally
preset)
No delay
Delay: 0,5 s
Presetting of the trip delay
of the undervoltage function
Delay: 1 s
Delay: 2 s
Delay: 3 s
Delay: 4 s
Delay: 5 s
Summary of Contents for VM1