8.2
General installation instructions
-
Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device).
-
Do not install the system controller directly next to the bell transformer or other power supplies (to avoid interference).
-
Do not install the wires of the system bus together with 100 V - 240 V wires.
-
Do not use common cables for the connecting wires of the door openers and wires of the system bus.
-
Avoid bridges between different cable types.
-
Use only two wires for the system bus in a four-core or multi-core cable.
-
When looping, never install the incoming and outgoing bus inside the same cable.
-
Never install the internal and external bus inside the same cable.
The following installation situations must be avoided:
-
Direct light
-
Direct sunlight
-
Extremely bright picture background
-
Highly reflective walls on the opposite side of the door station
-
Lamps or direct light sources