Commissioning

Product manual 2TMD041900D0015

43

During setting, please swipe the same admin card.

Function

Action

Unlock indicator

Exit settings

Swipe admin card 1x or no
cards swiped within 15 seconds

--

Function

Action

Unlock indicator

Open a door

Swipe the enrolled keycard

Green

Reset to factory default

Press and hold the 1st button for
3 s to enter configuration mode.

3 LED: flash green

Press and hold the 1st button for
10 s to reset to factory default.

3 LED: OFF

Reboot the device

Door open LED: red, green,
orange cycle flash

Technical data of ID card

Work frequency

Standard

125KHz

EM4100, EM4205, EM4305, EM4450, TK4100, T5567/T5577

Note

A maximum of 64 ID cards can be supported by mini outdoor station.

Summary of Contents for Welcome IP H8131.P. Series

Page 1: ...2TMD041900D0015 21 10 2019 Product manual ABB Welcome IP H8131 P H8131 P 02 H8136 P H8136 P 02 Mini video outdoor station ...

Page 2: ...ing the nameplate 17 7 9 Installation situation 18 8 Commissioning 19 8 1 Configure the settings on indoor station 19 8 1 1 Outdoor station enters engineering mode 19 8 1 2 Indoor station enters engineering settings 20 8 1 3 Device settings 21 8 1 4 Lock management 23 8 1 5 Door status detection 24 8 1 6 Sound 25 8 1 7 Anti ficker setting 26 8 1 8 Set the function of pushbutton 27 8 1 9 Time sync ...

Page 3: ...to a user 44 8 4 2 Assigning the locks to a user 47 8 4 3 Removing ID authentications from a user 48 9 FCC 49 10 Cyber security 50 10 1 Disclaimer 50 10 2 Performance and service 50 10 3 Deployment guideline 51 10 4 Upgrading 51 10 5 Backup Restore 51 10 6 Malware prevention solution 51 ...

Page 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Page 5: ...Intended use Product manual 2TMD041900D0015 5 3 Intended use As part of the ABB Welcome IP system this device can only be used with accessories from that system ...

Page 6: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 7: ...1900D0015 7 5 Product description 5 1 Control elements No Description 1 Indicator flashes slowly ringing Indicator flashes quickly busy line 2 Call indicator 3 Unlock indicator 4 Speaker and microphone integration 5 Round pushbutton 4 5 1 2 3 ...

Page 8: ... Connector for the sensor used for door status detection 2 Connector for exit button 3 Plug in clamps LOCK AGND for door opener 4 Plug in clamps COM NC NO for floating output 5 Plug in clamps DC GND for standalone power supply 6 LAN PoE 7 N A DS NC COM NO GND DC LAN 1 2 3 4 5 6 7 LOCK AGND EXIT ...

Page 9: ... to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT PS PS Type A Type B Type C ...

Page 10: ... 24 V 350 mA Operating temperature 40 C 55 C Product dimensions 99 mm x 168 mm 26 mm H8131 P 105 mm x 180 mm 43 mm H8136 P Camera type CMOS Camera viewing angle 104 Power supply for door opener 15 V 4A impulse max 250 mA holding Floating output for door opener 30 V 3 A IP level IP 54 IK level IK 07 Network connection standard IEEE802 3 10 100 Mbps auto MDI MDI X ...

Page 11: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 12: ...Mounting Installation Product manual 2TMD041900D0015 12 7 2 Preparation Use gloves to protect yourself from being cut 7 3 Installation height 7 4 Wiring 1 50 m 5 feet LAN ...

Page 13: ...oduct manual 2TMD041900D0015 13 7 5 Surface mounted installation Product dimension Surface mounted on the wall 99 mm 26 5 mm 78 mm 62 mm 62 mm 83 mm 60 mm 168 mm 147 mm 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Page 14: ...Mounting Installation Product manual 2TMD041900D0015 14 Surface mounted on the box e g VDE box 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Page 15: ...uct manual 2TMD041900D0015 15 7 6 Flush mounted installation Product dimension Flush mounted with pre installation box 105 mm 180 mm 53 mm 174 mm 99 mm 45 mm 99 mm 174 mm 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Page 16: ...lation Product manual 2TMD041900D0015 16 7 7 Cavity wall installation Product dimension Mounting 105 mm 180 mm 43 mm 90 mm 168 mm 92 mm 97 mm 120 mm 170 mm Screw shaft 4 Screw length 25 mm Mounting screw x 4 1 2 3 4 5 ...

Page 17: ...Mounting Installation Product manual 2TMD041900D0015 17 7 8 Replacing the nameplate 3 4 6 5 1 2 2 ...

Page 18: ...ion situation Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources ...

Page 19: ...he same network with the indoor station Please follow the steps below Power up the mini outdoor station three indicators light green After a period of time three indicators light down Hold the first pushbutton for 5 s When the pushbutton module and three indicators flash green at the same time the mini outdoor station enters the engineering mode Pushbutton module First pushbutton Unlock indicator ...

Page 20: ...ers engineering settings On the extra screen of indoor station click System to access the corresponding screen On the System settings screen click Engineering settings enter the engineering password and then click Outdoor station settings to access the corresponding screen ...

Page 21: ... Product manual 2TMD041900D0015 21 8 1 3 Device settings On the Outdoor station settings screen select the device type 2nd OS 1 Location Internal With this setting 2nd OS is connected to the router in the apartment ...

Page 22: ...oduct manual 2TMD041900D0015 22 2 Location External With this setting 2nd OS is connected to the switch outside the apartment Note The external and internal types cannot be used in mixed scenarios in the same apartment ...

Page 23: ...reen No Function 1 Unlock type when swiping Set the lock to be released when swiping Default lock default Subsidiary lock 2 Lock type Set the lock type for the default lock and subsidiary lock Lock GND NO NC COM IP actuator 3 Time of unlock Set the time for unlock Power lock Lock GND Signal lock NO NC COM ...

Page 24: ...n If this function is enable the outdoor station will send an alarm to the management software if the door is open longer than 120 s A sensor should first be connected to the outdoor station 2 Tamper proof alarm If this function is enabled the outdoor station will send an alarm to the management software if the outdoor station is removed from the wall ...

Page 25: ...of outdoor station Click or to adjust the ringtone volume and the voice volume on the outdoor station 2 Button tone Tick the checkbox to enable button tones on the outdoor station 3 Voice prompt Tick the checkbox to enable voice prompts on the outdoor station Choose the language for the voice prompts from the drop down list ...

Page 26: ...Commissioning Product manual 2TMD041900D0015 26 8 1 7 Anti ficker setting On the Outdoor station settings screen select the refresh rate from the drop down list ...

Page 27: ...MD041900D0015 27 8 1 8 Set the function of pushbutton On the Outdoor station settings screen click Pushbutton address setting to access the settings of the pushbuttons Note Device no should be entered if Phone guard unit is selected ...

Page 28: ...8 8 1 9 Time sync setting On the Outdoor station settings screen If Sync time with management is selected the outdoor station will sync the time from the management software If Close time sync is selected the time and date needs to be set manually ...

Page 29: ...Commissioning Product manual 2TMD041900D0015 29 8 1 10 Compatible mode setting On the Outdoor station settings screen the outdoor station is set to Security mode by default Compatible mode off ...

Page 30: ...re update Note The outdoor station doesn t need to enter engineering mode when you want to upgrade the firmware On the Outdoor station settings screen click Firmware update select the outdoor station and the file from SD card then click OK to update the firmware ...

Page 31: ...Commissioning Product manual 2TMD041900D0015 31 8 1 12 Version information On the Outdoor station settings screen view the version information ...

Page 32: ...Commissioning Product manual 2TMD041900D0015 32 8 1 13 Serial number On the Outdoor station settings screen view the serial number this number is used to get the signature from the management software ...

Page 33: ...Commissioning Product manual 2TMD041900D0015 33 8 1 14 Signature On the Outdoor station settings screen view the signature ...

Page 34: ...ate can be added by SmartAP This mini outdoor station will lose its certificate if its physical address is changed The mini outdoor station needs to be powered on before being added On the configuration screen of SmartAP following the steps below Note If the mini outdoor station is installed in the community network Installed in the coummnuty network should be enabled ...

Page 35: ...Commissioning Product manual 2TMD041900D0015 35 8 2 2 Configure the settings On the configuration screen click Door entry system Outdoor stations then click a mini outdoor station to access the settings ...

Page 36: ...on 1 Device ID 2 Click the icon to return to the previous screen 3 Overview of the outdoor station 4 Device type of the outdoor station 5 Display the address of the outdoor station 6 Display the serial number of the outdoor station 7 Display the version of the outdoor station ...

Page 37: ...address for the outdoor station 2 1 Set the unlock time for default lock and subsidiary lock 3 Enable or disable the time synchronization with the management software 4 Update the firmware via local PC 5 Update the firmware via the external website 6 2 Set the trusted devices for the outdoor station ...

Page 38: ...Commissioning Product manual 2TMD041900D0015 38 1 Set the door lock time It the default lock type is set to IP actuator following the steps below ...

Page 39: ...Commissioning Product manual 2TMD041900D0015 39 On the designated IP actuator screen following the steps below ...

Page 40: ...Commissioning Product manual 2TMD041900D0015 40 ...

Page 41: ...15 41 2 Set the trusted devices On the designated mini outdoor station screen following the steps below Note You need to enable the Trust this management software function if you want this outdoor station to unlock in the event of an emergency ...

Page 42: ...dmin card Swipe card 1x Green Enter settings Swipe admin card 1x Orange After entering settings following functionalities can be implemented Function Action Unlock indicator Enroll user Swipe admin card 1x Orange flash 1x Swipe user card 1x Green Delete user Swipe admin card 2x Orange flash 2x Swipe user card 1x Green Enroll new admin Swipe admin card 3x Orange flash 3x Swipe new admin card 1x Gre...

Page 43: ...e the enrolled keycard Green Reset to factory default Press and hold the 1st button for 3 s to enter configuration mode 3 LED flash green Press and hold the 1st button for 10 s to reset to factory default 3 LED OFF Reboot the device Door open LED red green orange cycle flash Technical data of ID card Work frequency Standard 125KHz EM4100 EM4205 EM4305 EM4450 TK4100 T5567 T5577 Note A maximum of 64...

Page 44: ...Commissioning Product manual 2TMD041900D0015 44 8 4 Card management on SmartAP 8 4 1 Assigning ID authentications to a user On the designated user screen following the steps below ...

Page 45: ...Commissioning Product manual 2TMD041900D0015 45 Registered ID authentications by card no When multiple card numbers are registered the card numbers are separated using ...

Page 46: ...Commissioning Product manual 2TMD041900D0015 46 Register by outdoor station recommend Swipe the ID authentications before the outdoor station when the prompt window appears ...

Page 47: ...s to a user The ID cards assigned to this user can release all the locks assigned to this user Note A maximum of 64 ID cards can be supported by mini outdoor station If more than 64 ID cards have registered by the user you can t assign the mini outdoor station to this user ...

Page 48: ...Commissioning Product manual 2TMD041900D0015 48 8 4 3 Removing ID authentications from a user On the designated user screen following the steps below ...

Page 49: ...s equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful...

Page 50: ...r losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third party ...

Page 51: ...de to remove the device from system user shall reset the device to factory setting in order to remove all the configuration data and sensitive data in the device This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 10 4 Upgrading Device supports firmware updates via management software a signature file will be used to veri...

Page 52: ...d specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 53: ...e No 16 Y Dudullu Istanbul T 90 216 528 2281 F 90 216 528 2945 ABB KSA Electrical Industries Co Ltd P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Thailand Ltd 161 1 SG Tower 1st 4th Floor Soi Mahadlekluang 3 Rajdamri Road Lumpini Pathumwan Bangkok 10330 Thailand T 66 2 6651 000 F 66 2 6651 043 ABB Russia Ltd Electrification Smart Buildings Nakhimovskiy prospekt 58 117335 Russ...

Page 54: ...Error Use the Home tab to apply Überschrift 1 to the text that you want to appear here Product manual 2TMD041900D0015 54 Copyright 2019 ABB All rights reserved ...

Reviews: