Cyber security
Product manual 2TMD041900D0015
│
50
10
Cyber security
10.1
Disclaimer
H8131.P.-. products are designed to be connected and to communicate information and data
via a network interface, which should be connected to a secure network. It is customer‘s sole
responsibility to provide and continuously ensure a secure connection between the product and
customer‘s network or any other network (as the case may be) and to establish and maintain
appropriate measures (such as but not limited to the installation of firewalls, application of
authentication measures, encryption of data, installation of antivirus programs, etc.) to protect
the H8131.P.-. product, the network, its system and interfaces against any kind of security
breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or
information. ABB and its affiliates are not liable for damages and/or losses related to such
security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or
information.
Although ABB provides functionality testing on the products and updates that we release, you
should institute your own testing program for any product updates or other major system
updates (to include but not limited to code changes, configuration file changes, third party
software updates or patches, hardware change out, etc.) to ensure that the security measures
that you have implemented have not been compromised and system functionality in your
environment is as expected.
10.2
Performance and service
Network performance
Type
Value
Ethernet
24 Mbps (37,449 packets/sec)
ARP
12 Mbps (18,724 packets/sec)
ICMP
22 Mbps (34,328 packets/sec)
IP
22 Mbps (34,328 packets/sec)
Port and service
Port
Service
Purpose
5070
UDP
To be used by SIP client.
7777
TCP/UDP
To be used for device management.
10777
TLS
Secure channel for device management
7005
TCP
To be used for connectivity detection when this feature is enabled.
8887
TCP
To be used for firmware update.