Operation Manual / 4 Product description / A100-L
4 Monitoring during operation / 4.1 Oil pressure, oil temperature
© Copyright 2020 ABB. All rights reserved.
HZTL4034_EN
Rev.P
January 2020
If the turbocharger was operated for a longer period of time outside of the admissible
range, ABB Turbo Systems recommends to have the turbocharger inspected by an ABB Tur-
bocharging Service Station.
4.1.1
Pre-lubrication and post-lubrication
CAUTION
Pre-lubrication
Serious damage to engine or property can result if the turbocharger is not
supplied with oil from the first moment after starting the engine.
u
Activate the pre-lubrication device each time before starting the engine.
The pre-lubrication time is at least 5 minutes.
The post-lubrication time is at least 10 minutes.
If the engine is operated for 5 to 10 minutes in idle mode before stopping, no additional
post-lubrication is required.