Operation Manual / 4 Product description / A100-L
8 Disassembly and assembly / 8.23 Fitting the filter silencer with noise
package
© Copyright 2020 ABB. All rights reserved.
HZTL4034_EN
Rev.R
October 2020
1. Position segments of the gasket (81301) on threaded studs of the compressor cas-
ing (72000).
2. Attach the lifting gear to the front lug and rear eyelet of the filter silencer (81000), paying
attention to the version of the filter silencer.
3. Position filter silencer on compressor casing.
4. Fit nuts (72004) with washers (72003) and insulating discs (81302) and tighten.
5. Fit insulation ring (81300).
6. Fit air outlet silencer (74040) with gasket (74042) and secure with counter-sunk
screws (74043).
u
Fit insulation as far as necessary.