Operation Manual / A100-L
10 Taking a turbocharger out of operation / 10.2 Taking defective tur-
bochargers out of operation
© Copyright 2021 ABB. All rights reserved.
HZTL4034_EN
Rev.T
December 2021
CAUTION
Machine damage due to overheating
Serious damage to engine or property can be caused by the overheating of
intact turbocharger components.
u
If there is a lubricating oil leak on the turbocharger, stop the oil supply.
10.2
Taking defective turbochargers out of operation
In the event of turbocharger damage, the turbocharger must be taken out of operation. In
order to ensure that the engine can continue operation as quickly as possible, observe the
following instructions.
10.2.1
Procedure with one turbocharger installed per engine
u
Stop the engine.
u
Close off oil supply to defective turbocharger.
u
Dismantle filter silencer (see chapter
Dismantling the filter silencer
).
u
Lock rotor with locking device (see chapter Locking the rotor)
Version
Procedure
With bypass
Open bypass
(see chapter
Engines with bypass around the turbocharger
Without bypass
If necessary, remove the nozzle ring
(see chapter
Engines without bypass around the turbocharger
)
Table 46: Bypass procedure
u
Continue to operate engine in accordance with enginebuilder's instructions. Observe the
prescribed power reduction.
Page
108
/
141