AN-79
SS ZMT
ZMT Dimensional Details
Identification Table for ZMT
Note 2.
Reference air options 2 and 3 have the air outlet inside the
enclosure to suit ZFG2 probe type. Flow rate 500 to 1000 ml/
min (0.11 to 0.22 gal/min.) approx.
Reference air options 1 and 4 for use on ZGP2 probe types
have both inlet and outlet connections external to the
enclosure.
Approvals
CEGB Approval Number 51042A0114 (5124A24) Issue 5.
Lloyds Approval for shipboard use obtained and awaiting
certificate.
Quality Assurance to BS5750 Part 1. Certificate number
Q5907.
Note 1.
Fuel options available:
00 No fuel specification
09 Distillate oil
01 Natural gas
10 No. 4 fuel oil
02 Propane
11 No. 5 fuel oil
03 Butane
12 No. 6 fuel oil
04 Medium oil
13 Coal (general)
05 Heavy oil
14 Bituminous coal
06 General fuel oil
15 Steam coal
07 Naphtha
16 Anthracite
08 Kerosene
17 Coke
Basic
Type
Ref.
Probe
Type
Ref. Air
Supply
(See
Note 2)
Probe
Temp.
Control
Fuel
Option
(See
Note 1)
Efficiency
Unused
Output
Module 1
Output
Module 2
Output
Module 3
Mains
Voltage
Code
Digit
Nos.
1,2,3
/4
5
/6
7,8,9,10
11
12
/13
14
15
16
ZMT
1 ZGP2
0
1
4
None
Pump+Air
Gauge
Regulator
0 None
1st
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
2nd
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
0 None
0 None
0
4
None
Analog
+ Relay
0
1
4
None
One
Relay
Analog
+ Relay
0
1
2
None
One relay
Two relays
1
2
110V
50/60Hz
230V
50/60Hz
2 ZFG2
0
2
3
None
Regulator
Pump
1 Temp.
Control
1
2
Efficiency
Humidity
0 None
0
4
None
Analog
+ Relay
0
1
4
None
One
Relay
Analog
+ Relay
0
1
2
4
None
One Relay
Two Relays
Analog
+ Relay
3 Other
0
1
4
None
Pump+Air
Gauge
Regulator
0
1
None
Temp.
control
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182E-MAIL: szss20@163.com
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL: szss20@163.com